Inserting the rear rack battery:
1
Open the lock cylinder: please ensure that the key is removed from the lock cylinder
2
Place the battery onto the battery docking station
3
Gently push the battery in a forward direction, towards the battery connector
Make sure the battery is inserted all the way, flush with the docking station cover
4
Push in the lock cylinder until a ‘click’ is heard
Removing of the rear rack battery:
1
Turn off the system via the console (no illustration)
2
Turn the key in the lock cylinder until it pops out
3
Remove the key from the lock cylinder
4
Pull the battery backwards, along the battery rail
Handling and Charging the Battery
WARNING
BionX batteries shall only be recharged with BionX chargers or BionX power supplies. The
use of other power supplies/chargers can damage the battery. Never short circuit the bat-
tery by connecting the contacts of the battery. Never open the battery, as this could dam-
age the battery and possibly lead to overheating. The battery cannot be serviced by the
user. Opening the battery case voids all warranty and product liability claims. Never use a
battery which has obvious damage to the case(s) or the battery connector.
001
001001
001001
2
3
4
WARNING
Do not force the battery onto the battery docking station. This can damage the battery
connector, or damage the rear light. Never unplug any connection with the system turned
on - this includes the battery. Pulling a live part can render it inoperable! If a battery is re-
moved while the system is turned on, wait 5 minutes until it turns off before re-installing.
A series of 5 beeps will indicate the battery has shut off and it is safe to install again.
001001
001001
1” (25.4mm)
001
CLICK
1
2
3
4
Inserting or Removing the Battery
Inserting the down tube battery
1
Place the battery onto the docking station
2
Slide the battery down the rail gently towards the connector
3
The release arm will begin to move to the closed position as the battery slides towards the connector
4
When the release arm is almost closed, hold it in place and simultaneously push in the lock cylinder –
you will hear a “click” when the lock cylinder is properly closed
Removing the down tube battery
1
Turn off the BionX propulsion system via the console (no illustration)
2
Lightly press on the battery release arm, insert the key and turn clockwise
The lock cylinder will pop out, freeing the battery release arm
3
Remove the battery by opening the release arm
4
Slide the battery upwards on the rail
5
Lift the battery to remove
25.4mm (1”)
001
001
25.4mm (1”)
001
001
1” (25.4mm)
001
001
2
3
4
5
WARNING
Do not force the battery release arm closed, or force the battery onto the battery dock.
This can damage the battery connector. Never unplug any connection with the system
turned on - this includes the battery. Pulling a live part can render it inoperable! If a bat-
tery is removed while the system is turned on, wait 5 minutes until it turns off before re-
installing. A series of 5 beeps will indicate the battery has shut off and it is safe to install