Temp Set (80
°F/26.0°C to 104°F/40.0°C)
The start-up temperature is set to 100
°F (37.5°C). The last measured temperature is constantly
displayed on the Liquid Crystal Display (LCD). Note: The spa temperature displayed is only current when
the pump has been running for at least 2 minutes.
Warmer/Cooler
Press WARMER or COOLER button once to display the set temperature. Press WARMER or COOLER
to increase or decrease the temperature. After three seconds, the LCD will automatically display the last
measured spa temperature.
Time
To set the time press TIME then MODE/PROG. Use the WARMER or COOLER buttons to adjust time.
Press MODE/PROG to switch to minutes. Press TIME to confirm. Note: Time settings are not preserved
in the event of a power loss; time will have to be reprogrammed each time.
Spa Modes
Press MODE/PROG to enter mode, press COOLER to cycle through modes, press MODE/PROG to
confirm mode.
Standard Mode: maintains the desired temperature. The STANDARD icon will display.
Economy Mode: heats the spa to the set temperature only during filter cycles. Press JETS 1
while in Economy mode will put the spa in Standard-In-Economy mode (SE), which operates the
same as Standard mode however, it will revert to Economy mode automatically after 1 hour. The
ECONOMY icon will display.
Standby Mode: helpful when changing a filter or a Jetpak. Press WARMER then JETS 2 or AUX
to start mode, to exit this mode press any button.
Sleep Mode: heats the spa to within 20
°F (11 °C) of the set temperature during filter cycles only.
The SLEEP icon will display.
Jets 1
Press JETS 1 to turn pump 1 on or off and to shift between low and high speeds. The low speed will turn
off after 4 hours and the high speed will turn off after 30 minutes.
Low speed of pump 1 may activate for at least 2 minutes every 30 minutes to detect the spa temperature
(polling) and will heat to set temperature if needed. When the low speed turns on automatically, it cannot
be turned off from the control panel.
Jets 2 (optional)
Press JETS 2 once to turn pump 2 on and off and to shift between low and high speeds. If left running,
the pump will turn off after 30 minutes. Note: An optional auxiliary control button on the side of the spa
can activate either pump.
Invert
Press WARMER or COOLER followed by the OPTION button to change the direction the numbers
display.
Light
Press LIGHT to turn the light on or off. The light will turn off automatically after 4 hours.
LED Light (optional)
Press LIGHT to turn on light. Press LIGHT again to shift through color options. The light will turn off
automatically after 4 hours.