  • Page 1

    Imix ® -5s+ hot & iced installation & operating guide bunn-o-matic corporation post office box 3227 springfield, illinois 62708-3227 phone: (217) 529-6601 fax: (217) 529-6644 to ensure you have the latest revision of the operating manual, or to view the illustrated parts catalog, programming manual,...

  • Page 2

    Page 2 41802.1 080112 bunn-o-matic commercial product warranty bunn-o-matic corp. (“bunn”) warrants equipment manufactured by it as follows: 1) airpots, thermal carafes, decanters, gpr servers, iced tea/coffee dispensers, mcp/mca pod brewers thermal servers and thermofresh servers (mechanical and di...

  • Page 3

    Page 3 warning ! Fill water tank before turning - on - thermostat or connecting appliance to power source. Use only on a properly protected circuit capable of the rated load. Electrically ground the chassis. Follow national/local electrical codes. Do not use near combustibles. Failure to comply risk...

  • Page 4

    Page 4 electrical requirements caution - the dispenser must be disconnected from the power source until specified in electrical hook-up. The 120 volt version of this dispenser has an attached cordset. The mating connector must be a nema 5-15r. To access terminal block for high voltage models without...

  • Page 5

    Page 5 plumbing requirements this dispenser must be connected to a cold water system with operating pressure between 20 and 90 psi (138- 620 kpa) from a 1⁄2” or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is...

  • Page 6

    Page 6 rinse timer the dispenser is shipped from the factory with the rinse timer disabled. To enable the rinse timer, refer to pro- gramming the dispenser and select yes in the “rinse alarm ?” screen; set timer to the desired time and exit the programming mode. When enabled, the rinse timer automat...

  • Page 7

    Page 7 cleaning the use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all sur- faces on bunn-o-matic equipment. Do not clean this equipment with a water jet device. 41802.1 072413 1 x 24h 37254.0003a 02/13 © 2013 bunn-o-matic corporation notice the cl...

  • Page 8

    Page 8 cooling fan switch for low temperature tank settings of approximately 90°f or over, leave the cooling fan switch, located inside the front door, in the “off” position. For low temperature tank settings under 90°f, place the cooling fan switch in the “on” position. A low end temperature of abo...

  • Page 9

    Page 9 adjust hot tank temperature (190° f maximum) adjust minimum hot tank ready temperature for lockout (185° f maximum) adjust hopper motor speed for station selected hot tank xxx° (-) exit (+) ready temp xxx° (-) exit (+) drink strength (-) xx (+) xx° cal xx° (-) hot tank (+) 235 refill 155 (-) ...

  • Page 10

    Page 10 d igital b everage c ontrol d igital b everage c ontrol stop program home screen the screen above will be shown when the dispenser is ready for use. While the tank is heating, the water temperature will be displayed until the ready temperature is reached. Programming the dispenser the follow...

  • Page 11

    Page 11 programming cup sizes - portion control models the cup size can be programmed in portion control models by “example” or “time”. Programming by ex- ample is manually pressing desired dispense button, then releasing when the desired cup size is attained. The time required to fill the cup will ...

  • Page 12

    Page 12 portion control ? No exit yes press and release right switch (advance to next menu), “tank temp xxx°” appears on screen. Programming the dispenser (cont.) hot tank xxx° ready temp xxx° (-) exit (+) strength adj. ? (-) exit (+) exit yes enter password (-) xxxx (+) calibration ? Exit yes locks...

  • Page 13

    Page 13 xx° cal xx° (-) hot tank (+) programming the dispenser (cont.) drink strength 1 (-) xx (+) press dispense to check taste taste 1 ok ? No yes (b) adjust hopper motor speed for station selected select units eng exit metric (d) 235 refill 155 (-) exit (+) auger delay (-) .Xx sec (+) returns to ...

  • Page 14

    Page 14 programming the dispenser (cont.) rinse alarm ? No exit yes head 1 disable ? No exit yes set password ? (-) xxxx (+) returns to (g) (page 11) test switches ? Use switch to test test heater ? Exit yes test refill ? Exit yes test warm htr ? Exit yes test augers ? Dispense to test test dispense...