Cambridge Audio Incognito LM10 Installation Manual - page 8
8 Incognito LM10
CAT-5 CONNECTIONS
A Cat-5 cable is used to connect the LM10 to a keypad output on an AH10 hub and to a KP10
amplified control module. Use Cat-5 cables (use EIA/TIA 568A RJ-45 wire configuration, see page
7) to connect from the hub to a LM10 wall plate (optional), and then wire from the wall plate to
the KP10 (see opposite diagrams). The LM10 has punchdown connectors for the eight individual
conductors of the Cat-5 cable, use a punchdown tool (LM10-EU=Krone, LM10-CU=110+ blade)
to insert conductors. If using shielded Cat-5 cable, connect the shields to the green terminal
blocks as shown in the opposite diagrams (dotted lines).
Note: When wiring directly to the LM10, crimp on a male RJ-45 connector using the EIA/TIA 568A
RJ-45 wire configuration (see Wiring Guide: EIA/TIA 568A wiring standard on page 7) for connec-
tion to the hub.
Single local audio source
Connect the LM10 as shown in the diagrams. Switch over SW1 (LC1) to the ON position and SW2
(LC2) to the OFF position. The LM10 will respond to the Local 1 remote command when selected.