Canon i-SENSYS D450d Service Manual - page 167
Chapter 14
14-11
14.2.9.2 Bit 7 and 8 Elaborated
0020-2781
i-SENSYS MF4300dn / i-SENSYS MF4350d / i-SENSYS MF4380dn / i-SENSYS MF4310/4318 / i-SENSYS MF4320d / i-SENSYS MF4330d / i-SENSYS
MF4340d / i-SENSYS D450d / i-SENSYS MF4370dn
Enables to set the duration of pause.
It is a combination of Bit 7 and Bit 8 and the duration is as listed below.
T-14-10
14.2.10 SSSW-SW37
14.2.10.1 Function List
0020-2782
i-SENSYS MF4300dn / i-SENSYS MF4350d / i-SENSYS MF4380dn / i-SENSYS MF4310/4318 / i-SENSYS MF4320d / i-SENSYS MF4330d / i-SENSYS
MF4340d / i-SENSYS D450d / i-SENSYS MF4370dn
T-14-11
14.2.10.2 Bit 1 to Bit 6 Elaborated
0020-2783
i-SENSYS MF4300dn / i-SENSYS MF4350d / i-SENSYS MF4380dn / i-SENSYS MF4310/4318 / i-SENSYS MF4320d / i-SENSYS MF4330d / i-SENSYS
MF4340d / i-SENSYS D450d / i-SENSYS MF4370dn
Enables to select the maximum baud rate in V.34 primary channel from 2400, 2800, 3000, 3200, 3429 baud.
Different combinations of Bit 1 to Bit 6 lead to different baud rates as shown below.
In Sending
T-14-12
In Receiving
T-14-13
(Bit7, Bit8)=
(0, 0) 2.0 seconds
(1, 0) 2.5 seconds
(0, 1) 3.0 seconds
(1, 1) 3.5 seconds
Bit
Function
1
0
1
V.34 Maximum Baud Rate (TX)
1
0*
2
V.34 Maximum Baud Rate (TX)
1
0*
3
V.34 Maximum Baud Rate (TX)
1
0*
4
V.34 Maximum Baud Rate (RX)
1
0*
5
V.34 Maximum Baud Rate (RX)
1
0*
6
V.34 Maximum Baud Rate (RX)
1
0*
7
Not in Use
-
-
8
Not in Use
-
-
(Bit1, Bit2, Bit3)=
(0, 0, 0) 3429
(1, 0, 0) 3200
(0, 1, 0) 3000
(1, 1, 0) 2800
(0, 0, 1) 2400
(Bit4, Bit5, Bit6)=
(0, 0, 0) 3429
(1, 0, 0) 3200
(0, 1, 0) 3000