Canon imageCLASS MF3111 Service Manual - page 67
Chapter 3
3-19
3.1.11.11
Removing the Power
Supply Shield Plate
0007-7547
1) Remove the 5 screws [1] to remove the power
supply shield plate [2].
F-3-75
3.1.11.12
Removing the Power
Supply Assembly
0007-7550
1) Remove the 3 screws [1].
2) Remove the 4 connectors [2] as well as the flat
cable [3] on the ECNT board.
F-3-76
3) As you remove the bosses on both sides [1], lower
the front part of the power supply assembly [2].
Then pull it to remove the power supply assembly.
F-3-77
3.1.11.13
Removing the Top
Sensor
0007-7552
1) Place the main unit down on its front face (so that
the interior of the main unit is easily visible).
2) Remove the connector [1] on the ECNT board and
take the cable off the cable guide.
3) Remove the screw [2] and remove the top sensor
[3].
F-3-78
[1]
[1]
[2]
[1]
[2]
[2]
[1]
[3]
[1]
[2]
[1]
[2]
[3]