Conlan CT1000 User Manual

Summary of CT1000

  • Page 1

    Secure open conlan aps • speditorvej 2a • dk-9000 aalborg • tel: +45 72 40 60 03 • fax: +45 96 32 00 22 www.Conlan.Eu • info@conlan.Eu keypad ct1000 art. No.: 460100 (black) art. No.: 460106 (white) user manual ct1000_usermanual_engmay15.

  • Page 2

    2 table of content 1. Introduction 2. Installation 3. Programming users 3.1 positions 3.2 programming the user codes 4. Advanced configurations 4.1 service code 4.2 configuration overview 4.3 changing the master code 4.4 changing the service code 4.5 led indication 4.6 output time 4.7 function setti...

  • Page 3

    3 1. Introduction ct1000 is a flexible keypad for many different applications. In standby the yellow led is lit ( ● ○ ○) correct code lights the yellow and the green led ( ● ● ○) incorrect code lights the red led (○ ○ ● ) ct1000 has a buzzer for indicating while keying, correct code, incorrect etc. ...

  • Page 4

    3. Programming users 3.1 positions ct1000 has 28 positions, which can contain a code from 1 to 8 digits. The code in position 1 is 1234 (default) 3.2 programming the user codes the master code is used to program/change/delete the users. By deafualt the master code is 4711. Led indication: no light: ...

  • Page 5

    5 4. Advanced settings 4.1 service code the service code is used for ct1000’s advanced settings such as changing the master code and service code, led indication and much more. The overview of the settings and the facto- ry settings can be seen in 4.2 configuration overview. The service code is 1234...

  • Page 6

    6 4.3 changing the service code the service code is used to cofigure the ct1000’s settings. To change the service code, enter the following: ○ ● ○ ● ● ○ * * ○ ○ ● ○ 4.5 led indication ct1000’s 3 led’s can be adjusted at will. Put the desired values together (e.G. Yellow as normal, yellow and green a...

  • Page 7

    7 4.7 function settings these settings is used to change ct1000’s function e.G. To use the service code without pow- er down and up, mute the buzzer etc. The overview below shows the values for the different functions. On off buzzer 0 1 toggle mode for 8 digits codes 2 0 service code with power on/o...

  • Page 8

    5. Blocking (duress) the ct1000 is blocked for 1 minute after 4 incorrect codes. Indication: ○ ○ * 6. Manuel reset ct1000 can be reset to default settings manually. Turn off the voltage, connect the yellow and brown wire, turn the power on again and the readers led’s light and the buzzer sounds. Whe...