1. Introduction
CT1000 is a flexible keypad for many different applications.
In standby the yellow LED is lit (
●
○ ○)
Correct code lights the yellow and the green LED (
●
●
○)
Incorrect code lights the red LED (○ ○
●
)
CT1000 has a buzzer for indicating while keying, correct code, incorrect etc. and 2 transistor
outputs with open collector for controlling of locks etc.
CT1000 is a stand alone unit, that can be programmed directly by Master Code and Service
Code.
2. Installation
• Mount the reader (use the drilling guide for proper alignment).
• Connect the wires to the power supply, lock unit, assembly box etc.
• Apply voltage 9 VDC, max. 25 VDC.
Note: Right after applying the voltage all LED’s light and the buzzer sounds do not touch the
reader untill the yellow LED lights and the buzzer is silent.
9 - 25 VDC / 30 mA
0V GND
Output 2 open collector, 500 mA, 0V active
External controlling green LED, 0V active
Output 1 open collector 500 mA, 0V active
External buzzer
External controlling red LED, 0V active
REX, 0V active