Conlan CT1000 User Manual - page 7
7
4.7 Function Settings
These settings is used to change CT1000’s function e.g. to use the Service Code without pow-
er down and up, mute the buzzer etc.
The overview below shows the values for the different functions.
On
Off
Buzzer
0
1
Toggle mode for 8 digits codes
2
0
Service Code with power on/off
4
0
Output (yellow wire) inverted
8
0
Hold function
16
0
Lock L2H
32
0
Lock H2L
64
0
4 digits code without # (rolling code)
128
0
Put the desired values together and enter them in “Key in value”.
To change the function settings, enter the following:
○
●
○
●
●
○
○
●
○
4.8 Activating the Output with Codes/Bell
This function is by default set that all codes activate the yellow output and the bell key acti-
vates the white output (value = 29). If the white output also should activate by codes key in 1
to 27 as value, it is the position after the entered value that starts to activate the white out-
put.
To change theses settings, enter the following:
○
●
○
●
●
○
○
●
○
It is the position after the entered value that starts to activate the white output.
#
Key in the
Service Code
#
Key in
05
#
Key in value
#
Key in the
Service Code
#
Key in
06
#
Key in value
1 to 27