Conlan CT1000 User Manual - page 5
5
4. Advanced settings
4.1 Service Code
The Service Code is used for CT1000’s advanced settings such as changing the Master Code
and Service Code, LED indication and much more. The overview of the settings and the facto-
ry settings can be seen in 4.2 Configuration Overview.
The Service Code is
12347890 (factory default).
Note: Before the Service Code can be used the voltage must be turned off and on (the Ser-
vice Code can no.
After entering the Service Code the reader is in programming mode (the green LED lit).
Each time a setting is made, the CT1000 goes back to the previous point and the next setting
can be made. The navigation is by entering the configuration number and
#
4.2 Configuration Overview
Config. no.
Setting
Default
00
Master Code (1 to 8 digits)
4711
01
Service Code (1 to 8 digits)
12347890
02
LED indication
31
03
Output time (white)
5
04
Output time (yellow)
5 (for codes)
05
Function settings
0
06
Activation with codes/bell
29
2500
All codes on position 1 to 28 is deleted
0250
Reset to factory default
4.3 Changing the Master Code
By factory is the Master Code
4711 and can only be used to program, change or delete users
on the CT1000.
To change the Master Code, enter the following:
○
●
○
●
●
○
○
●
○
#
Key in the
Service Code
#
Key in
00
#
Key in a new
code