Connect Tech Xtreme/10G User Manual - Switch Details
Xtreme/10G Managed Ethernet Switch/Router
Users Guide
www.connecttech.com
Document: CTIM-00472
Revision: 0.04
Page 14 of 24
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2017-07-27
Switch Details
DIP Switch Details (S1)
Ensure – S1 Lower Switch Position is set to “RUN” at all times.
Moving the switch to “RESET” will hold the entire device in RESET and will prevent the board from booting.
Typical Installation
1. Install XHG201 heatplate to XDG201 module.
2. Prepare breakout/carrier board with 4 x M3 8mm standoffs.
3. Ensure breakout/carrier board will be supplying module with +12V DC.
4. Mate board-to-board connector from XDG201 module to that of the breakout/carrier board.
5. Turn power ON to breakout/carrier board, XDG201 will now boot up.
On-Board Indicator LED’s
The XDG201 has 2 on-board indicator LEDs.
LED Designator
Description
PWR
Power Good Indicator
-
If this LED is ON, this indicates that all on-board
power supplies are ON and at the proper level.
Status
System Status Indicator
-
Function TBD