SW3… Switch 1 (1.Remote_1) to ON, Switch 2 (2.Remote_2) OFF, Switch 3
(3.Ph_conn1) OFF, Switch 4 (4.Ph_conn2) ON.
If installing 2 pairs of beams simply repeat the above sequence and change the
following: Run the wire from normally closed to FO2 and change SW3 switch 3 to ON.
Installing optional wired Probe or vehicle detector to double gates:
Note: EasyGate recommend installing safety beams in conjunction with a probe to stop
the gates hitting an obstruction such as a vehicle while in a closing cycle.
If installing WITHOUT safety beams.
From the EMX VMD202-R Probe: Positive red to “+12” on the Terrier board (J2). Black to
“G”. Green (negative) to “G” and white (normally closed) to “FO2”.
SW1: 1 OFF, 2 ON, 3 OFF, 4 OFF, 5 ON, 6 ON, 7 ON and 8 OFF (20 sec auto close time)
SW2: 1 OFF, 2 ON, 3 OFF, 4 OFF and 5,6,7,8 to ON
SW3: 1 ON, 2 OFF, 3 ON and 4 OFF
Note: If installing 2 probes connect only 1 green wire from 1 probe and the white from
the other. Take the remaining white and green wires from opposite probes and twist
these together so it is in series.
If installing WITH safety beams.
From the EMX VMD202-R Probe: Positive red to “+12” on the Terrier board (J2). Black to
“G”. Green (negative) to “G” and white (normally closed) to “FO2”.
When installing safety beams power both slave and master beams at “+12” positive and
“G” negative.
N/C of the beam master to J2 “FO2” and Com of the beam to “G” (terminal 6)
SW1: 1, 2, 3 and 4 OFF, 5, 6 and 7 to ON and 8 OFF (20 sec auto close)
SW2: 1 OFF, 2 ON 3and 4 OFF, 5, 6, 7 and 8 to ON
SW3: 1 to ON, 2, 3, and 4 OFF
Using one remote to activate a different Terrier system installed within 50m of
the other.
Use the DIP SW3 1. remote_1 & remote_2
One with A for dual gate; B for single gate. One with C for dual gate; D for single gate
then you can have both Terrier units using the same 4 channel remote
Explanation of Terminal block J2 (left)
1. +12V External device 13.7v Dc power positive (+).
1. G
Ground/Negative/common (-).
2. FO1 Signal for Photo beam 1
3. FO2 Signal for Photo beam 2 (used where 2 x pairs of beams are used)