Fitting the arm cable:
Step 1
– Remove the cover screws.
Step 2
– Push up the cover
slightly.
Step 3
– Some models have a 2 x tab system while others have 3 x screw
fasteners. On the back, insert a flat head screw driver in slots, push forward tabs to
release hooks
Step 5
– Insert cable from under motor via the cable hole and cable clamp
and fasten motor wires to connector block. Use a minimum 1.5mm 2 core cable, not a
telecom or network cable.
Installing Control Box: Location of the control box must be within 10m of the arms
and approximately 1m plus off the ground. The gates must be able to open and close
freely without swinging into the control box.
Wiring Double Gate Arms to control box: To protect the
cable place into PVC pipe or in concrete driveways, place into
an expansion joint (the cut line in concrete to assist
expansion).
Extend the arm cable so they can reach the control box with some spare. Connect each
arm into the control board to the far right connector blocks labelled Mo1+, Mo1- (motor
1) and Mo2+, Mo2- (motor 2). See image below. On double gates one arm cable will
need to go under the driveway. As the arm motor have yellow and white cables fitted,
you do not need to match these in colour back to the control board just the
symbols…..you can see we have used brown and blue cable below. You will not damage