EasyGate Terrier 200 Installation Manual - page 7
7
Double Gate System Learn: This must be completed when first installing the control
board so the computer can understand the parameters of the new installation.
1. Check you have SW2 Set DIP switch 8 to ON
2. Press the SYS-learn button which is next to the RF-learn button in the top left
corner. Hold it in for 5 seconds. It will start flashing once every second now.
3. Press the remote top left corner button. The rams will now start to move one
at a time (This can take up to 20 seconds to start activating). The rams will
move in one of the following orders:
Dual-Gates: Gate 2 closes, gate 1 closes, gate 1 opens, gate 2 opens, gate 2
closes, and gate 1 closes. You will hear the relays clicking. This is normal. It
DOES NOT matter if the gates are open, closed or half way when installing the
automation. The system will automatically work out the size of the swing. It will
open and close each side individually 3 times before it has finished installing the
system. This is normal.
4. After the systems learn has finished, LED no.1 should be revert back to
flashing in bursts. You have successfully set up your gate opener kit and is
now ready for testing.
Pedestrian mode: To open a gate for a pedestrian simply press the top RIGHT hand
button. This will open one gate to a 45 degree angle. (You do not need to reinstall the
remote or button for this function).
Single Gate System Learn: This must be completed when first installing the control
board so the computer can understand the parameters of the new installation.
1. Connect the arm into the control board connector blocks labelled Mo1+, Mo1-
2. Set the SW1 DIP7. P/Mode to OFF position, for single gate fully open/close
3. Set the SW2 DIP8. D/S Set to OFF position, for single gate operation
4. Set the SW3 1.Remote_1 to ON ; 2.Remote_2 to ON position, for remote
button (A) to operate the open/stop/close of the single gate
5. Press the “RF-learn button” on the PCB for 3secs, and press the remote
button (A) the top left button, and wait until blue light turns off (up to 10 sec)
6. Press the “SYS-learn” on the PCB for 5secs, and press the remote button (A)
for single gate system learning process (Gate will go through the process
automatically, please wait for it to stop )