Ecobee SMART THERMOSTAT Installation Manual - page 15
Common Heat/Cool Settings
Heat Differential Temp
The minimum difference
between the current temperature and set temperature
before the system calls for heat. A smaller difference
means a more comfortable environment, whereas a
larger difference is more economical.
Heat Dissipation Time
The amount of time the fan
will run after the heat set point has been reached and
the call for heat has been turned off. Running the fan
for a period of time allows for any heated air left in the
ducts to circulate throughout the home.
Cool Differential Temp
The minimum difference
between the current temperature and the set
temperature.
Cool Dissipation Time
The amount of time the fan
will run after the cool has been turned off. Running
the fan for a period of time allows for any cooled air left
in the ducts to circulate throughout the home.
Temp Correction
This will allow you to program an offset between what
temperature the thermostat is measuring versus what
is displayed. If you find that the temperature where
the thermostat is located does not represent the room
temperature, this offset allows you to compensate for
that difference.
Installer Code
This option lets you enable or disable 3262 as the
installer code.
Test Equipment
This section allows you to manually turn on and off the
various equipment connected to the Equipment Interface,
in order to test the wiring and connections.
Warning: Compressor protection and minimum run-time
features are not enforced while in this mode.
In any of the screens within this section, the equipment
will turn off when you select Done.
25 Configuring The Smart Thermostat
Sensors
This section allows you to configure the detector inputs
on the Equipment Interface. This can be used to connect
optional flood sensors, or other leak-detection devices.
Once an input has been triggered, it will generate an
alert on the touch screen and send an e-mail if the
thermostat has been registered with a web portal.
Each input can be configured as normally open, where
a short-circuit between the IN1+ and IN1 will activate
the alert, or normally closed, where an open circuit will
activate the alert.
To activate any input, select the input and program a
name. To deactivate the input, simply delete the name.
View Wiring Diagram
This feature allows you to view the terminal connections of
the equipment interface as determined by the configuration
options selected during the installation process.
Contractor Info
This section allows you to enter your contact information.
It will be displayed to the homeowner in the About
menu, when any alert is shown on the touch screen and in
his personal web portal. You can enter your:
Company name
Phone number
Email address
Website address.
If you are a registered ecobee contractor, you will
have access to your Contractor portal. In this portal,
you can enter the serial number of each ecobee
Smart Thermostat you install. Once your registered
thermostats are connected to the Internet, your
contact information, including your company logo,
will be automatically loaded onto them.
Reset Installation Settings
Selecting this option will restore all the installation settings
back to the factory default. Any user setting (not related to
the equipment installed) will remain unchanged.
Configuring The Smart Thermostat 26