EMotionLighting EML1205 Instruction Manual - Instructions
EML1205 INS
Rev: Jul 2013
pg. 7/12
Instructions
C. Controls (cont’d)
7.
Saving Settings
• The device will automatically retrieve saved settings upon power up and
changing patterns.
• Speeds and patterns are saved by the following rules:
1. One minute after the last button is pressed.
• At the same time the setting is saved (one minute idle), the display
turns off.
2. When a different pattern is selected.
• The current speed is saved for the current pattern when one of the
pattern buttons is pressed to select a different pattern.
3. Medley Mode (Patterns 97-99)
• Medley Mode automatically selects patterns according to the list
on page 3. The speed of each pattern can be changed while
Medley has the pattern selected.
• Rules 1 and 2 apply to saving speeds in Medley Modes.
D. User Defined Pattern #51 – (For Advanced Users)
Pattern numbers 00 – 50 are pre-defined by the manufacturer and cannot be changed.
Pattern 51 can be customized by the user to create simple patterns. This is done by
configuring the User Defined Settings (Patterns 52-81).
Patterns 52-81 are only available when the speed of Pattern 00 is set to 39 (it’s maximum
or “Hi”). Setting Pattern 00 to another speed makes Patterns 52-81 unavailable in normal
operation. This helps prevent your customized pattern from being accidentally changed.
Each user defined Output has a:
Dwell - Time for the output to remain off when Pattern 51 is initiated
Level 1 - Power Level for the Output after the Dwell is complete
Time 1 - Time for Level 1 to remain on (minimum is 1)
Level 2 - Power Level for the Output after Time 1 at Level 1 is complete
Time 2 - Time for Level 2 to remain on (minimum is 1)
When Time 2 at Level 2 is complete, Level 1 for Time 1 is re-initiated. Level 1 and
Level 2 continue to alternate.
Hint: If you want an output to be a single power level, make both Level 1 and
Level 2 the same value.