Standard, Display, Timer/Thermostat RF Remote Handset
•
Simultaneously press and hold the OFF and (large flame)
buttons until a short acoustic signal confirms the start
sequence has begun; release buttons.
•
Continuing signals confirm the ignition is in process.
•
Once pilot ignition is confirmed, there is main gas flow.
•
After the ignition the remote will go automatically into tem-
perature control mode (CSA-versions) or manual mode
(CE-versions)
TO TurN OFF THe APPLIANce
Press OFF button on remote handset.
NOTE: Press (small flame) to turn main gas to pilot gas.
TO OPeN AND cLOSe SOLeNOID VALVe/BurNer
NOTe: The latching solenoid valve will not operate for one min-
ute after ignition.
The latching solenoid valve cannot operate
manually. If the battery runs down it will remain in the last
operating position. During normal operation the solenoid
valve will be reset into the ON position when the GV60 is
switched OFF remotely.
•
Upon ignition both Burner and Decorative Burner are ON.
•
Press upper left and lower right button simultaneously to
switch the Burner OFF (printed instructions are located on the
battery cover).
•
Press upper left and upper right button simultaneously
to switch the Burner ON. (Display and Timer/Thermostat
Remote Handsets: the AUX symbol on the display will
indicated that the solenoid valve is OPEN.)
ADJUSTMENT - FLAME HEIGHT
Standard, Display, Timer/Thermostat RF Remote Handsets
•
In standby mode: Press (large flame) to increase flame
height.
•
Press (small flame) to decrease flame height or to set
appliance at pilot flame.
•
For fine adjustment tap the large/small flames.
SETTING °C/24 HOUR OR °F/12 HOUR CLOCK
Display, Timer/Thermostat RF Remote Handsets
•
Press OFF and (small flame) until display changes from
Fahrenheit/12 hour clock to Celsius/24 hour clock and vice
versa.
SeTTING THe TIMe
Display, Timer/Thermostat Remote Handsets
•
This display will flash after either:
a. Installing the battery or
b. Simultaneously pressing the (large flame) and
(small flame).
•
Press (large flame) to set the hour and the (small flame)
to set the minute.
•
Press OFF to return to manual mode or simply wait and it will
automatically return to the manual mode.
Remaining Instructions pertain to Timer/Thermostat RF
Remote Handset only
cHANGING THe MODe OF OPerATION
Briefly pressing the SET button changes the mode of operation in
the following order:
MAN
TEMP
TEMP
TIMER
and back to
MAN
NOTe: MANUAL mode can also be reached by pressing either
the (large flame) or the (small flame).
MAN
Mode - Manual Flame Height Adjustment
•
Press (large flame) to turn on the main burner.
•
Press (large flame) to increase the flame height.
•
Press (small flame) to decrease the flame height or to go to
pilot standby position.
NOTe: While pressing either button a symbol indicating
transmission appears on the display. The receiver
confirms transmission with an acoustic signal.
TEMP
- Daytime Temperature Mode
(appliance must be in standby mode; pilot ignited):
The room temperature is measured and compared to the set
temperature. The flame height is then automatically adjusted to
achieve the Daytime set temperature.
TEMP
- Nighttime Setback Temperature Mode
(appliance must be in standby mode; pilot ignited):
The room temperature is measured and compared to the Night-
time Setback temperature. The flame height is then automatically
adjusted to achieve the Nighttime Setback temperature.
TIMER
- Timer Mode
(appliance must be in standby mode; pilot ignited):
The Timer setting allows you to set two (2) burner
TEMP
times
every 24 hours.
For
TEMP
to operate as a thermostat, TEMP must be set at 40°F
(4°C) or higher.
G6R-P3TAN5 REMOTE CONTROL INSTRUCTIONS