Empire Comfort Systems VFSE-18-1 Owner's Manual - page 19
28092-0-1110
Page 19
If the
TEMP
setting is decreased to --, the motor will turn the valve
to the standby position in the moon times and await the next burn-
er
TEMP
cycle.
NOTE: The display shows the set temperature every 30 seconds.
SeTTING THe TeMPerATure
•
Select either the
TEMP
MODE or the
TEMP
MODE by briefly
pressing the SET button.
•
Hold the SET button until the TEMP display flashes.
•
Set the desired temperature with (large flame) or (small
flame).
•
Press OFF or simply wait to complete programming.
SeTTING THe TIMer
•
Select Timer mode by briefly pressing the SET button.
•
Press and hold the SET button until the P1
(sun symbol)
is displayed) and the time flashes. Set the hour by pressing
the (large flame) and set the minutes by pressing the
(small flame).
•
Briefly press SET button for the next burner cycle time.
•
Example: P2
(moon symbol) continue through P2
(sun symbol) and P2
(moon symbol).
•
Once all four (4) times are set, press OFF or simply wait to
complete programming.
MANuAL OPerATION
(Only possible when MANUAL knob is used)
Follow appliance manufacturer’s instructions for gaining access to
the gas control and the pilot burner. Access to the pilot burner is
only required for ignition with a match.
When turning main valve knob, do not force. Knob has a slip clutch
that clicks until the end stops are reached. This allows for manual
flame height adjustment as well as adjustment to pilot standby po-
sition.
1. STOP! Read the safety information included before proceed-
ing.
2. Turn main valve knob to the OFF, full clockwise
position.
3. Turn MANUAL knob to the MAN, full clockwise
posi-
tion.
4. Place ON/OFF switch (if equipped) in O (OFF position).
5. Wait five (5) minutes to clear out any gas. Verify that no gas
is in the area around the appliance, including near the floor.
If
you detect gas STOP! Follow “A” in the safety information on
page 20. If no gas is present, proceed to step 6.
6. Place ON/OFF switch (if equipped in (ON position).
7. With the MANUAL knob in MAN position a manual pilot valve
operator and piezo igniter (optional) are accessible.
8. Fully push down manual pilot valve operator and hold
in, to start pilot gas flow.
Ignition with match:
Immediately light the pilot with a match, while continuing to
hold in the manual pilot valve operator for about one (1) min-
ute after the pilot is lit. Release manual pilot valve operator. If
pilot does not stay lit, wait five (5) minutes and repeat.
Ignition with piezo igniter:
Change the ignition cable from the receiver to the
valve. Use the push piezo igniter to ignite. If pilot does
not stay lit, wait five (5) minutes and repeat.
NOTE: If the pilot does not stay lit after several tries, turn the
gas control knob (main valve knob) to OFF and proceed to
step 11.
9. If applicable, per appliance manufacturer’s instructions,
replace pilot access panel before proceeding.
10. Turn MANUAL knob to the ON, full counterclockwise
position.
11. Turn main valve knob to the full ON, full counterclockwise
position.
12. If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE” and call the service technician or
gas supplier.
TurN OFF GAS TO APPLIANce
•
Press OFF button on remote or wall switch/touch pad/switch
panel.
•
Follow appliance manufacturer’s instructions for gaining
accessibility to the gas control.
•
Place ON/OFF switch (if equipped in O (off position).
•
Turn main valve knob to the OFF full
clockwise
position.
•
Replace appliance accessibility cover (if applicable), per
appliance manufacturer’s instructions.
MISceLLANeOuS
Low Battery Indication
Receiver:
three short beeps will sound when motor turns
Standard/Infrared remote:
the red LED will get darker
Remote with display:
“BATT” will appear on display
NOTe: Pertains to Thermostatic Display/Handsets: If the battery
of the handset is low or if the transmitter is out of the com-
munication range, the motor turns down the valve to pilot
gas after 6 hours.
NOTe: With very low battery the GV60 system shuts off the fire
completely. This will not happen if the power supply is
interrupted.
Battery replacement
Battery replacement is recommended at the beginning of each
heating season. Pull ribbon to remove batteries. Do not use metal
tools to remove batteries. Using a metal tool could cause a short
that may damage the receiver.
G6R-P3TAN5 REMOTE CONTROL INSTRUCTIONS