Empire Comfort Systems VFSE-18-1 Owner's Manual - Cleaning And Servicing
28092-0-1110
Page 24
Annual inspection and cleaning by your dealer or qualified
service technician is recommended to prevent malfunction
and/or sooting.
TurN OFF HeATer AND ALLOw TO cOOL BeFOre
CLEANING.
Remove logs, handling carefully by holding gently at each end.
Gloves are recommended to prevent skin irritation from ceramic
fibers. If skin becomes irritated, wash gently with soap and water.
Refer to manual for correct log placement.
PERIODIC CLEANING – Refer to parts diagram for location of
items discussed below.
•
Do not use cleaning fluid to clean logs or any part of heater.
•
Logs - brush with soft bristle brush or vacuum with brush
attachment.
•
Remove loose particles and dust from the burner areas,
controls, piezo covers and grate. Don’t remove media from
inside burner box.
•
Inspect and clean burner air intake hole. Remove lint or particles
with brush. Failure to keep air intake hole clean will result in
sooting and poor combustion.
ANNUAL CLEANING/INSPECTION – Refer to parts diagram for
location of items discussed below.
•
Inspect and clean burner air intake hole. Remove lint or particles
with vacuum or brush. Failure to keep air intake hole clean will
result in sooting and poor combustion.
•
Inspect and clean all burner ports.
•
Inspect ODS pilot for operation and accumulation of lint at air
intake holes.
•
Verify flame pattern and log placement for proper operation.
•
Verify smooth and responsive ignition of main burner.
•
Check level of ceramic media in burner. Burner should be full,
up to the level of openings in burner top.
VFSV
Note: (Wiring harness located in envelope)
Connect black/red 3/16" terminal wire from receiver to 3/16" terminal
on valve. Connect black 1/4" terminal wire from receiver to 1/4"
terminal on valve. Install remote receiver cover over receiver when
receiver is installed into fireplace area. Locate receiver and cover to
the right and forward of valve. (Do not put receiver behind logs).
cLeANING AND SerVIcING
wIrING
MA
GR
MO
SW
P
ANEL
SW
TC
SPARK
O
I
IGNITION CABLE
THERMOCOUPLE
RF ANTENNA
THERMO CURRENT
CABLE #1
ON/OFF SWITCH
8 WIRE CABLE
INTERRUPTER
BLOCK
COMBINATION CONTROL
MANUAL KNOB
PIEZO IGNITER
MAIN VALVE KNOB
CONNECTION FOR
MANUAL IGNITION
THERMO CURRENT
CABLE #2 OR ON/OFF
SWITCH WITH SOLDERED CABLE
BUTTON “RESET”
BATTERY
COMPARTMENT
VFSE Wiring Diagram
VFSV Wiring Diagram
ADJ.
LEARN
OFF
REMOTE
THERMOCOUPLE
(NATURAL)
THERMOCOUPLE
(LPG)
Figure 18