FAAC B680H Manual - page 10
9
ENGLISH
Changes to the configuration parameters become
effective immediately, while final storage occurs
only upon exiting configuration and returning to the
automated system status display. If the equipment is
powered down before returning to the automated system
status display, all changes made will be lost.
5.1 Basic configuration
ToperformBASICprogramming:
1. Press and hold button
F; the name of the first function is
displayed.
2. Releasethebutton;thefunctionvalueisdisplayedandcanbe
modifiedusingthe+and-buttons.
3. Press and hold
Fagain;thenameofthefollowingfunctionis
displayed,andsoon.
ThelastfunctionStletsyouchoosewhethertosavetheconfiguration
made(
Y
)orexitwithoutsaving(
no
).Later,thedisplaywillresume
showingtheautomatedsystemstatus
You can go to St at any time. To exit programming,
simultaneously press F and -.
BASIC CONFIGURATION
Display
Function
Default
dF
Loading predefined parameter sets
00
Neutralcondition
0 1
Minimummass
06
Maximummass
Beforeautomatedsystemstart-up,youmust
setthecorrectvalue,directlycorrelatedtothe
lengthofthebeamandthenumberandtype
of accessories installed. To determine said
value,refertoTables4and5onpage24
WARNING: Setting a mass default
lower than the one actually
installed could cause irreversible
damage to the bar and barrier
structure.
Ifyoudonotwishtomakeanyprogramming
changes, leave the value
00
, otherwise
selectingavalueinvolvesloadingthechosen
predefined parameters set (see paragraph
5.2).
00
At
Currently loaded default
This menu indicates the currently loaded
defaultsetting.
Given that parameter
dF
has
00
as the
predefinedvalue(inordertoprovideaneutral
accessconditiontotheparameters),usingthe
valueinthismenumakesitpossibletoidentify
thecurrentlyconfigureddefaultsetting.
Read-only parameter
06
Display
Function
Default
bu
BUS accessories menu
Forfunctionsassociatedwiththisparameter
seeparagraph5.3
no
LO
Operating logics
A
Automatic
A 1
Automatic1
E
Semi-automatic
P
Parking
PA
Automaticparking
Cn
Condo
CA
Automaticcondo
C
Dead-man
CU
Custom
E
PA
Pause time
Is effective only if an automatic logic is
chosen; the value can be set from
O
to
59
sec. in one second steps. Next, the
displaychangestominutesandtenthsofa
second(separatedbyadecimalpoint)and
timeisadjustedin10-secondstepsuptothe
maximumvalueof
4.1
minutes.
e.g.ifthedisplayshows
2.5
,thepausetime
willbe2minutesand50seconds.
20
So
Opening speed
Adjuststhebarrieropeningspeed.
00
Minimumspeed
1 0
Maximumspeed
WARNING: Setting an excessive speed
could cause irreversible damage to the
beam and barrier structure.
10
Sc
Closing speed
Adjuststhebarrierclosingspeed.
00
Minimumspeed
1 0
Maximumspeed
WARNING: Setting an excessive speed
could cause irreversible damage to the
bar and barrier structure.
02
L 1
Loop 1
Activating this parameter, any loop that is
connectedtotheLoop1inputwillserveas
anOPENfunction.
Y
Loop 1 enabled
no
Loop 1 disabled
Note: Should this function be disabled, the
detectionstatusoftheloopwillinanycase
remainavailableononeofthetwooutputs,
if configured (see parameters
o1
...
o4
in
AdvancedConfiguration)
no