FAAC B680H Manual - page 11
10
ENGLISH
Display
Function
Default
L2
Loop 2
Activating this parameter, any loop that is
connectedtotheLoop2inputwillserveasa
SAFETY/CLOSEfunction.
Y
Loop 2 enabled
no
Loop 2 disabled
(see note regarding Loop 1)
no
S 1
Loop 1 sensitivity
Adjuststhesensitivityofthevehicledetection
loop
00
Minimumsensitivity
1 0
Maximumsensitivity
05
S2
Loop 2 sensitivity
Adjuststhesensitivityofthevehicledetection
loop
00
Minimumsensitivity
1 0
Maximumsensitivity
05
Mt
Motor movement
Usingthefunctionprovidedbythispara-
metermakesitpossibletomanuallymove
thebarrierbar,operatingasdead-man.
Pressing+willopentheautomatedsystem,
pressing-causestheautomatedsystemto
close.
oP
pressing
+,open
cL
pressing
-,close
--
St
AUTOMATED SYSTEM STATUS:
Thisallowsyoutochoosewhethertoquittheprogramme
and save the data.
Y
=quitandsavethedata
no
=quitwithoutsavingthedata
Onquittingtheprogramme,pressthe
Fkeytodisplay
thestatusoftheautomatedsystem
00
Beam closed
0 1
Beam open
02
Stationaryreadytoopen
03
Stationaryreadytoclose
04
Automatedsystempaused
05
Opening
06
Closing
07
Failsafeinprogress
08
2-EASYdeviceverificationinprogress
09
Pre-flashingthenOPENS
10
Pre-flashingthenCLOSES
1 1
EMERGENCY Open
You can go to St at any time by simultaneously
pressing F and -.
Displaying of the automated system status
St
is extremely
important for the installing/maintenance technician in order
to distinguish the logical processes that the board carries
out during movement.
If, for example, the automated system status is CLOSED,
the display MUST read
00
. When the OPEN command is
received, the display will change to
09
, if pre-flashing is
enabled, or directly to
05
(the OPENING movement) to then
display
0 1
once the position of gate OPEN is reached).
Exampleofastatussequencedisplayedstartingfromaclosedbarrier
00
Beam closed
05
Opening
0 1
Beam open /
04
Pause
06
Closing
The sequence does not include statuses
09
and
10
which
correspond to pre-flashing when opening and closing,
respectively.
5.2 Changing the predefined parameters set
TheE680boardfeaturessixsetsofpre-definedconfigurationsthat
allowrapidadaptingtothesizeofthebeaminstalled,makingitthe
startingpointforafineadjustmentoftheparameters.Toselectone
of the available configurations, you must change the parameter
dF
from the pre-set value
00
(neutral condition) to the value
correspondingtothebarrierconfiguration(beamlength,typeand
numberofaccessoriesinstalled)showninTables4or5onpage
24(e.g.choosedefault
04
forabeammeasuring5minlength
withfootandlights).
To complete configuration, it is necessary to exit the Basic
Configurationmenubypressing“F”untilparameter
St
is reached
orbypressing“F”and“-”