FAAC B680H Manual - page 13
12
ENGLISH
DL1 LED description (Red)
On
Atleastoneoftheinputs(safeties,OPENpulse)is
engagedoractive
Off
NoOPENinputisactiveandnosafetydeviceis
engaged
DL2 LED description (Green)
On
fixed
Normallyactive(LEDoneveniftherearenodevices
connected)
Off
BUS-2EASY line short-circuited (flash every 2.5
sec.)
Rapid
flashing
An error has been detected in the BUS-2EASY
connection;repeattheacquisitionprocedure.Ifthe
errorpersists,checkthat:
•
the system does not have more than one
accessory with the same address (see also
instructionsregardingtheaccessories)
•
makesurethereisnocallingerror(numberof
devicesconnectedisgreaterorlessthanthat
storedduringsetup)
6. Advanced Configuration
To accessAdvanced Configuration, press
Fand, while holding it,
also press
+
:
•
when
+
isreleased,thenumberofthefirstavailablefunction
will appear
•
when
F is also released, the value is displayed, and can be
changedusing
+
and
-
•
pressing
Fagain,andholdingit,thenameofthenextparameter
will be displayed; when released, the value can be changed
using
+
and
-
•
oncethelastfunctionhasbeenreached,pressing
F makes it
possibletoeithersavethepreviouslychangedparametersorexit
withoutsavingthechanges;thedisplaywillgobacktoshowing
thestatusoftheinputs.
ADVANCED CONFIGURATION
Display Function
Default
FO
Opening motor power
Adjuststhethrustofthemotorduringtheope-
ningphase.
00
Minimumpower
50
Maximumpower
40
FC
Closing motor power
Adjuststhethrustofthemotorduringtheclosing
phase.
00
Minimumpower
50
Maximumpower
40
PF
Pre-flashing
Thisparameterisusedtoactivatetheflashing
lamp for 5 seconds before the selected
movement.
no
disabled
OC
before each movement
CL
beforeeachclosingmovement
OP
beforeeachopeningmovement
PA
onlyattheendofthepause
no
Display
Function
Default
tP
Pre-flashing time
Pre-flashingtimeexpressedinseconds.
00
minimumpre-flashing
10
maximumpre-flashing
00
oc
Sensitivity of obstacle during closing
This determines the sensitivity to an obstacle
beforereversingtakesplace.
0 1
Minimumsensitivity
50
Maximumsensitivity
0 1
o 1
Output 1
Settingthisfunctionmakesitpossibletomodify
the signal type of output 1, allowing high
connectionflexibilitywithexternaldevices.
00
Failsafe
0 1
TYPE 1 BEAM ILLUMINATION (output
active when beam closed, disabled
with bar open or paused, intermittent
when moving).
Use only with output
4!
02
DISABLED
03
Beam CLOSED
04
BeamOPENorinPAUSE,itgoesoff
duringclosingpre-flashing.
05
BeaminOPENINGMOVEMENT,
includingpre-flashing.
06
BeaminCLOSINGMOVEMENT,
includingpre-flashing.
07
Beam STATIONARY
08
Beam in EMERGENCY mode
09
LOOP1engaged
10
LOOP2engaged
1 1
OPEN for E680 slave
12
CLOSE for E680 slave
13
Beam RELEASED
14
Notused
15
Notused
16
FCAengaged
17
FCCengaged
18
Notused
19
WARNING LAMP (on during opening
and pause, flashing when closing, off
whentheautomatedsystemisclosed)
04