Fadini COMBI 740 Instruction Manual - page 8
8
PIC. 17
PIC. 16
PIC. 15
DIP-SWITCH B
Now commence the electrical work. Connect the control panel
ELPRO 13 exp as per pictures 16 and 18.
Important: Should N.C. contacts eg. Photocells, Stop Button and
safety contact not exist, link out individually. If the operators run in
wrong direction reverse 17, 18 or 20, 21 respectively.
Once the connections have been made, set the dip-switch "B" as
required but with No. 3 "ON" automatic, pulse the radio transmitter or
short out terminals 7 - 8 momentarily and make sure that the operating
run and dwell times are as required, adjust through the rotary timers
7-8-9. See diagram ELPRO 13 exp. Picture 18.
The electrical equipment must be properly earthed.
Picture 17 shows an exemplary complete installation.
N.W.: CARRY OUT A RISK ANALYSIS IN COMPLIANCE WITH EN 12445
AND EN 12453 NORMS AND FIT ANY SAFETY DEVICE WHERE
REQUIRED.
n°
2x1
n
°4x1,5
n
°4x1,5
n°
4x1
n°
4x1
n
°4x1
n
°2x1
n°
4x1
n°
3x1,5
n°
2x1
11
12
13
14
1
2
3
4
5
6
7
8
9
10
15
16
16
®
DAMPENING
DAMPENING DEVICE
OUT OF SERVICE
IN SERVICE
OIL FILLER CAP
JUNCTION BOX
CUT OUT BRICKWORK
TO PROVIDE PROTECTION
FOR THE CONTROL BOX
Should the model with the dampening device be required to install
adjustment in the open and close cycles is by means of a screw
on the top of the jack end cap: with a screwdriver give one turn
clockwise. The dampening device is now in service and the gate
will "brake", ie. slow down speed over the last 40 cm of its angular
motion. One turn anti-clockwise will re-set to the standard operating
mode. Picture No. 15.
ELECTRIC P.C. BOARD
1 - MAINS SWITCH 230V - 50Hz
MAGNETIC-THERMAL DIFFERENTIAL 0.03A
(CABLES LONGER THAN 100 m ø 2,5 mm)
2 - JUNCTION BOX
3 - COMBINED JACK/MOTOR PUMP LEFT-HANDED
4 - CLOSED GATE STOP REQUIRED
5 - COMBINED JACK/MOTOR PUMP
RIGHT-HANDED
6 - POST WITH PHOTOCELL RECEIVER POLO 44
7 - POST WITH PHOTOCELL PROJECTOR POLO 44
8 - KEYSWITCH PRIT 19
9 - PHOTOCELL RECEIVER POLO 44
10 - PHOTOCELL TRANSMITTER POLO 44
11 - FLASHING LAMP MIRI 4
12 - AERIAL BIRIO A8
13 - RADIO RECEIVER ASTRO 43/1 R
14 - CONTROL BOX ELPRO 13 exp
15 - RADIO TRANSMITTER ASTRO 43/2 TR SMALL
16 - OPEN GATE STOP REQUIRED
NOTE WELL: EARTH CONNECT THE WHOLE SYSTEM