FG Wilson DCP-10 User Manual - page 25
DCP-10
Page 21/27
Datcon:
Murphy:
PT100:
Pre-set 1:
Pre-set 2:
Pre-set 3:
Pre-set 4:
Type 12
:
:
:
:
8.7 The optional items for configurable input:
Code
Optional Function
NOTE
0
not used
1
Pre-alarm (active immediately)
low level is active
2
Shutdown Alarm(active immediately)
low level is active
3
Pre-alarm (active after safety-on delay)
low level is active
4
Shutdown Alarm(active after safety-on delay)
low level is active
T(
℃
)
40
50
60
70
80
90
100
110
120
130
140
T(
℉
)
104
122
140
158
176
194
212
230 248
266
284
R(
Ω
)
900
600
400
278
200
141
104
74
50
27
4
T(
℃
)
40
50
60
70
80
90
100
110
120
130
140
T(
℉
)
104
122
140
158
176
194
212
230
248
266
284
R(
Ω
)
1029
680
460
321
227
164
120
89
74
52
40
T(
℃
)
-100
-50
0
20
40
60
80
100
150
200
300
T(
℉
)
-148
-58
32
68
104
140
176
212
302
392
572
R(
Ω
)
60
81
100
108
116
123
131
139
157
176
212
T(
℃
)
20
30
40
50
60
70
80
90
100
110
120
T(
℉
)
68
86
104
122
140
158
176
194
212
230
248
R(
Ω
)
900
600
420
282
152
113
86
62
48
40
30
T(
℃
)
30
50
60
70
80
90
100
110
120
T(
℉
)
86
122
140
158
176
194
212
230
248
R(
Ω
)
980
400
265
180
125
90
65
50
38
T(
℃
)
20
30
40
50
60
70
80
90
100
110
120
T(
℉
)
68
86
104
122
140
158
176
194
212
230
248
R(
Ω
)
805
540
380
260
175
118
83
58
42
30
21
T
(℃)
28
35
40
50
60
70
80
90
95
98
T
(℉)
82
95
104
122
140
158
176
194
203
208
R
(Ω)
579
404
342
250
179
136
103
77
67
63
T(℃)
150
130
110
90
80
70
50
25
0
0
R(Ω)
6.9
10.8
17.7
30.6
41.1
56.3
111.8
300
964.4 964.4