Galletti AREO 12 Technical Manual

Manual is about: AREO Series Air Conditioning fan heater

Summary of AREO 12

  • Page 1

    Gb air conditioning fan heater technical manual ventilconvettori fan coil units.

  • Page 2: Areo

    2 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo index 1 main features ................................................................. 2 2 unit description ............................................................. 3 3 constructive features ...................

  • Page 3: Areo

    3 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 2 unit description 1 3 5 6 7 8 9 10 11 12 2 4 (1) cabinet: side panel (2) cabinet: upper/lower panel (3) rear panel/fan compartment (4) finned block heat exchanger (heat exchanger coil) (5) safety grille (fan) sup...

  • Page 4: Areo

    4 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 5 rated technical data notes rated capacity determined at the following conditions: cooling mode:water temperature 7/12°c, air temperature 28°c dry bulb, 55% relative humidity heating mode: water temperature 85 / ...

  • Page 5: Areo

    5 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 6 heating capacity legend: pw pressure drop on water side pt heating capacity qw water flow rate tbs 1 inlet air temperature tbs 2 outlet air temperature tw 1 inlet water temperature tw 2 outlet water temperature...

  • Page 6: Areo

    6 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 6 heating capacity legend: pw pressure drop on water side pt heating capacity qw water flow rate tbs 1 inlet air temperature tbs 2 outlet air temperature tw 1 inlet water temperature tw 2 outlet water temperature...

  • Page 7: Areo

    7 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 6 heating capacity legend: pw pressure drop on water side pt heating capacity qw water flow rate tbs 1 inlet air temperature tbs 2 outlet air temperature tw 1 inlet water temperature tw 2 outlet water temperature...

  • Page 8: Areo

    8 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 6 heating capacity legend: pw pressure drop on water side pt heating capacity qw water flow rate tbs 1 inlet air temperature tbs 2 outlet air temperature tw 1 inlet water temperature tw 2 outlet water temperature...

  • Page 9: Areo

    9 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 6 heating capacity legend: pw pressure drop on water side pt heating capacity qw water flow rate tbs 1 inlet air temperature tbs 2 outlet air temperature tw 1 inlet water temperature tw 2 outlet water temperature...

  • Page 10: Areo

    10 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 6 heating capacity legend: pw pressure drop on water side pt heating capacity qw water flow rate tbs 1 inlet air temperature tbs 2 outlet air temperature tw 1 inlet water temperature tw 2 outlet water temperatur...

  • Page 11: Areo

    11 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 7 cooling capacity to prevent phenomena of condensate dripping, it is advisable to select indoor units capable of maintaining, when operating at full capacity, an air temperature below 35 °c and relative humidity...

  • Page 12: Areo

    12 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 7 cooling capacity to prevent phenomena of condensate dripping, it is advisable to select indoor units capable of maintaining, when operating at full capacity, an air temperature below 35 °c and relative humidity...

  • Page 13: Areo

    13 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 8 sound levels legend: lp a a - weighted sound pressure level (5m distance, 2 directional factor) lw octave band sound power level lw a a - weighted sound power level vr fan speed: 4 p = 4 poles, 1400 rpm 6 p = 6...

  • Page 14: Areo

    14 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 10 height of installation wall mounting legend: 4 p 4 poles, 1400 rpm 6 p 6 poles, 900 rpm 8 p 8 poles, 700 rpm hv maximum installation height ao throw distance bo floor influence area 11 height of installation c...

  • Page 15: Areo

    15 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo in out 25 38 a b c 300 141 150 206 31 66 66 d e 80 80 a g 3 1 2 Ø3.5 b b-15 b+31 a -15 a a +31 c c 12 overall dimensions areo basic unit legend: (1) water inlet connection (male gas coupling) (2) water outlet con...

  • Page 16: Areo

    16 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 12 overall dimensions pae fresh air intake 300 50 pae model air inlet hole in the wall aypae1 areo 12 - 13 - 14 392 x 392 400 x 400 aypae2 areo 22 - 23 - 24 492 x 492 500 x 500 aypae3 areo 32 - 33 - 34 592 x 592 ...

  • Page 17: Areo

    17 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 13 electrical data features of the standard motor: - tropicalised - equipped internally with a thermal cutout - ip 55 protection degree - class f winding - closed type: asynchronous three-phase 2-speed motors (40...

  • Page 18: Areo

    18 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo m gnye cn wh bk bu rd s rl 4 1 2 3 c cd 230v 50hz l f il n 3a 14 wiring diagrams m gnye 6 5 4 3 2 1 s cn wh bk bu rd cde c 230v 50hz l f il n wiring diagram showing connection of single-phase 3-speed motors, with...

  • Page 19: Areo

    19 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 14 wiring diagrams 6 5 n 4 3 2 1 acc s sf t c tc td 230v 50hz l f il n m gnye cn wh bk bu rd 3a wiring diagram showing connection of single-phase 3-speed motors, with td wall-mounted control. Bk black, maximum sp...

  • Page 20: Areo

    20 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo l1 l2 l3 n n 1 ta-ta2 1 3 5 2 4 6 2 a1 a2 k w1 w2 u1 u2 v1 v2 11 12 klixon m cst - cstp il f w2 u2 v2 u1 v1 w1 13 15 2 1 9 14 13 4 2 10 6 15 1 6 14 8 16 5 13 l 14 n 15 l 16 n 2 3 4 5 c 1 2 3 34 31 32 33 30 27 28 ...

  • Page 21: Areo

    21 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo mycomfort medium - wall-mounted microprocessor control, galletti model mycomfort medium having the following main features: - room air temperature reading and adjustment - room humidity reading and adjustment - w...

  • Page 22: Areo

    22 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo 15 accessories kp - power interface for connection of up to 4 units to a single control panel the kp master sleeve can be installed to control with a single control panel up to 4 units (connected in parallel). Th...

  • Page 23: Areo

    23 ap66000265 - 03 all copying, even partial, of this manual is strictly forbidden areo rated capacity determined at the following conditions: heating mode: water temperature 85 / 75°c, inlet air temperature 20°c fan speed: 6 p = 6 poles, 900 rpm 8 p = 8 poles, 700 rpm la - air curtain diffuser in o...

  • Page 24

    Company uni en iso 9001 and ohsas 18001 certified.