Garador Garage Door Opener Instruction Manual - page 18
©Copyright 2006
Garador
P/N: 05xxx
- 18 -
ACESSORIES
3.3 - Safety Infra-Red Beam - Part No 062153
For ADDITIONAL SAFETY protection we STRONGLY
recommend the fitting of a Safety Infra-Red Beam. In most
countries Safety Beams are mandatory on all garage doors
fitted with automatic openers. For a small additional outlay
Garador
recommends that Safety Infro-Red Beams be installed
with the automatic opener ensuring additional safety and
peace of mind.
Locate the IR Beam in a strategic location within doorway.
We recommend 150mm above the floor level and as close
as possible to the door opening, inside the garage and
connect the wires as per Fig. 20.
Note:
This opener is only compatible with
Garador
Transmitter/
Receiver type IR Beam (Order Code: 062153).
Make sure to align the beams correctly. Follow the manual
supplied with the IR Beam. Twist the wires from both
transmitter and receiver together before connecting to the
terminal block as per Fig. 20.
WARNING:
When using Auto Close Mode and IR beams,
the doorway must be clear of all obstructions and persons at
all times. The location of the beam and manner in which it is
installed might not give safety protection at all times. Check
to make sure that the height of the beam and type used give
maximum protection possible.
3.4 - Wired Wall Switch/Electric Key Switch
A wired wall switch or electric key switch can be connected
to the opener as an alternative to using the remote control
transmitter. The electric key switch doubles as an external
release mechanism which is ideal if your garage does not
have a pedestrian door.
To connect the switch to the opener’s terminal block refer to
Fig. 21.
The switch behaves just like a remote control transmitter:
each turn of the key will cycle through an open - stop - close
function.
Note:
For installation procedure of the Electric Key Switch/
Release please refer to the unit’s instruction sheet.
Fig. 20
Fig. 21
WHITE
GND
IR BEAM
30V PWR
OPERATE
CLS OUT
AUX OUT
Note: For the Safety IR Beam to be
recognised by the controller, it must be
installed and connected before the travel
limits are set. Refer to Step - 7 on Page 12.
GND
IR BEAM
30V PWR
OPERATE
CLS OUT
AUX OUT
WHITE W/BLACK