Garmin GMX 200 Installation Manual - page 97
GMX 200 Installation Manual
Page E-7
190-00607-04
Revision D
GARMIN
GDL 69/69A
P691
7
RS232 IN 3
25
6
2
5
4
NOTES:
1. ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
2. AT GMX 200, CONNECT SHIELD GROUNDS TO THE CONNECTOR BACKSHELL-- THE SHIELD LEADS
MUST BE LESS THAN 3.0 ". CONNECT OTHER SHIELD GROUNDS TO AIRCRAFT CHASSIS WITH AS
SHORT A CONDUCTOR AS PRACTICAL.
3. RS232 PORTS 1, 2, 4 OR 5 MAY BE USED INSTEAD OF PORT 3.
4. GMX 200 MUST BE CONFIGURED FOR THE GDL 69 SOURCE ON PORT 3 (OR WHICHEVER
RS232 OUT 3
SERIAL GROUND 3
PORT GDL 69/69A IS CONNECTED TO), AND THE FIS DATA LINK FUNCTION MUST BE ENABLED.
P2001
GMX 200 MFD
DATA LINK
RECEIVER
RS-232 OUT
RS-232 IN
SIGNAL GROUND
3
6
13
4
4
3
IF GDL 69A IS INSTALLED, THE XM SATELLITE RADIO FUNCTION MUST ALSO BE ENABLED.
s
Figure E-5. GDL 69/69A Data Link