Summary of GNC 420

  • Page 1

    Gnc and gns are trademarks of garmin ltd. Or its subsidiaries and may not be used without the express permission of garmin. (gns 430 shown) £ 190-00140-02, revision q october 2005 400 series installation manual gps 400, gnc tm 420 (a), and gns tm 430 (a).

  • Page 2

    Page a 400 series installation manual rev q 190-00140-02 © copyright 1998 - 2005 garmin ltd. Or its subsidiaries all rights reserved except as expressly provided herein, no part of this manual may be reproduced, copied, transmitted, disseminated, downloaded or stored in any storage medium, for any p...

  • Page 3

    400 series installation manual page i 190-00140-02 rev q this manual is written for software version 5.01, and is not suitable for earlier software versions. Information in this document is subject to change without notice. Visit the garmin web site (www.Garmin.Com) for current updates and supplemen...

  • Page 4

    Page ii 400 series installation manual rev q 190-00140-02 table of contents 1. General description 1.1 introduction .................................................................................................................................................1-1 1.2 equipment description.............

  • Page 5

    400 series installation manual page iii 190-00140-02 rev q list of figures figure 2-1. Gps antenna and unit installation considerations .............................................2-2 figure 3-1. Coaxial cable installation ...............................................................................

  • Page 6

    Page iv 400 series installation manual rev q 190-00140-02 list of figures - continued figure f-30. Rmi/obi interconnect.............................................................................................................F-61 figure f-31. King serial panel dme tuning interconnect................

  • Page 7

    400 series installation manual page v 190-00140-02 rev q 400 series hardware mod level history the following table identifies hardware modification (mod) levels for the gps 400, gnc 420 and gns 430. Mod levels are listed with the associated service bulletin number, service bulletin date, and the pur...

  • Page 8

    Page vi 400 series installation manual rev q 190-00140-02 this page intentionally left blank.

  • Page 9

    400 series installation manual page 1-1 190-00140-02 rev q 1. General description 1.1 introduction this manual describes the physical, mechanical, and electrical characteristics and the installation requirements for the 400 series (gps 400, gnc 420, and gns 430) panel-mounted units. After installati...

  • Page 10

    Page 1-2 400 series installation manual rev q 190-00140-02 1.3 technical specifications the conditions and tests required for tso approval of the 400 series are minimum performance standards. It is the responsibility of those desiring to install this article either on or within a specific type or cl...

  • Page 11

    400 series installation manual page 1-3 190-00140-02 rev q 1.3.2 general specifications operating temperature range -20 q c to +55 q c. For more details see environmental qualification form. Humidity 95% non-condensing altitude range -1,500 ft to 50,000 ft input voltage range (gps 400) 11 to 33 v dc...

  • Page 12

    Page 1-4 400 series installation manual rev q 190-00140-02 1.3.4 com transceiver specifications (gnc 420 and gns 430 only) ** regulatory compliance tso-c37d class 4 & 6* (3 & 5 for “a” models), tso-c38d class c & e, jtso-2c37e (etso-2c37e for the gns 430a), jtso-2c38e (etso-2c38e for the gns 430a), ...

  • Page 13

    400 series installation manual page 1-5 190-00140-02 rev q 1.3.5 vor specifications (gns 430 only) regulatory compliance tso c40c, jtso-2c40c (etso-2c40c for the gns 430a), rtca do-196, eurocae ed-22b receiver audio sensitivity at -103.5 dbm (s+n)/n shall not be less than 6 db. Course deviation sens...

  • Page 14

    Page 1-6 400 series installation manual rev q 190-00140-02 1.3.6 loc specifications (gns 430 only) regulatory compliance tso c36e, jtso-c36e (etso-c36e for the gns 430a), rtca do-195 class a, eurocae ed-46b receiver audio sensitivity at -103.5 dbm (s+n)/n shall not be less than 6 db. Course deviatio...

  • Page 15

    400 series installation manual page 1-7 190-00140-02 rev q 1.4 tso limitations a limitation exists pertaining to tso-c36e (localizer) and tso-c34e (glideslope). The main board lateral deviation (j4001 pin 21 main +left and j4001 pin 22 main +right) and vertical deviation (j4001 pin 27 main +up and j...

  • Page 16

    Page 1-8 400 series installation manual rev q 190-00140-02 fde is provided for oceanic and remote operations, non-precision approaches, en route and terminal phases of flight. Fde for non-oceanic flight phases adhere to the same missed alert probability, false alert probability, and failed exclusion...

  • Page 17

    400 series installation manual page 2-1 190-00140-02 rev q 2. Installation 2.1 introduction careful planning and consideration of the suggestions in this section are required to achieve the desired performance and reliability from the 400 series unit. Any deviations from the installation instruction...

  • Page 18

    Page 2-2 400 series installation manual rev q 190-00140-02 2.2.6 antenna limitations garmin’s ga 56 antennas are recommended for installations where the airspeed of the aircraft is subsonic. In such installations, ga 56—mod 1 or later—must be used. See the com, vor/loc, and glideslope antenna specif...

  • Page 19

    400 series installation manual page 2-3 190-00140-02 rev q 2.2.8 com, vor/loc, and glideslope antenna installation instructions install the com, vor/loc, and glideslope antennas according to the manufacturer’s recommendations. Avoid running other wires and coaxial cables near the vor/loc antenna cab...

  • Page 20

    Page 2-4 400 series installation manual rev q 190-00140-02 hsi/cdi indicator or efis this device displays nav flag, left/right, to/from, glideslope flag, and up/down. The indicator(s) used in conjunction with the gns 430 vor/ils receivers shall be tso'd. Qualified gps antenna this antenna must be on...

  • Page 21

    400 series installation manual page 3-1 190-00140-02 rev q 3. Installation procedure 3.1 unit and accessories the 400 series units are available under the following part numbers: 3.1.1 gns 430 (a) catalog p/n unit p/n gns 430a accessories (1) color operating voltage minimum xmit pwr 010-00139-00 011...

  • Page 22

    Page 3-2 400 series installation manual rev q 190-00140-02 3.1.2 gnc 420 (a) catalog p/n unit p/n gnc 420a accessories (1) color operating voltage minimum xmit pwr 010-00173-00 011-00506-00 n n black 28 10 w 010-00173-01 011-00506-00 n y black 28 10 w 010-00173-10 011-00506-10 n n black 14 or 28 vdc...

  • Page 23

    400 series installation manual page 3-3 190-00140-02 rev q the following installation accessories are available: 1. Gps antenna options: x ga 56 antenna kit, without cable (mod 1 or later, garmin p/n 010-10040-01). This kit contains the following items: item garmin p/n qty ga 56 antenna sub-assembly...

  • Page 24

    Page 3-4 400 series installation manual rev q 190-00140-02 3.2 data base options item garmin p/n data card, world wide 010-10201-00 data card, americas 010-10201-01 data card, international 010-10201-02 data card, taws/terrain* 010-10201-20 * required for terrain 3.3 miscellaneous options item garmi...

  • Page 25

    400 series installation manual page 3-5 190-00140-02 rev q caution do not use construction grade rtv sealant or sealants containing acetic acid. These sealants may damage the electrical connections to the antenna. Use of these type sealants may void the antenna warranty. 3.6 cable installation 1. Ro...

  • Page 26

    Page 3-6 400 series installation manual rev q 190-00140-02 table 3-1. Pin contact part numbers 78 pin conn (p4001) 44 pin conn (p4006) 25 pin connector (p4002) shield ground connector connector type high density pin contact standard density socket contact .1” pitch card-edge wire gauge 22-28 awg 18 ...

  • Page 27

    400 series installation manual page 3-7 190-00140-02 rev q 3.7 rack installation 1. The back plate of the rack may optionally be removed for ease of mounting in the aircraft panel. To do so, remove the two #4-40 screws, tilt the back plate away from the tray, and then slide the back plate to the sid...

  • Page 28

    Page 3-8 400 series installation manual rev q 190-00140-02 this page intentionally left blank.

  • Page 29

    400 series installation manual page 4-1 190-00140-02 rev q 4. System interconnects 4.1 pin function list 4.1.1 p4001 view of j4001 connector from back of unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 ...

  • Page 30

    Page 4-2 400 series installation manual rev q 190-00140-02 connector p4001, continued pin pin name i/o 37 altitude alarm audio hi (not implemented at time of publication) out 38 altitude alarm audio lo (not implemented at time of publication) out 39 lighting bus hi in 40 lighting bus lo in 41 gps rs...

  • Page 31

    400 series installation manual page 4-3 190-00140-02 rev q 4.1.2 p4002 (gnc 420 and gns 430 only) view of j4002 connector from back of unit 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 pin pin name i/o 1 reserved -- 2 reserved -- 3 reserved -- 4 com mic key in 5 intercom mic hi ...

  • Page 32

    Page 4-4 400 series installation manual rev q 190-00140-02 4.1.3 p4006 (gns 430 only) view of j4006 connector from back of unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 pin pin name i/o 1 vor/loc +to out 2 vor/loc +fro...

  • Page 33

    400 series installation manual page 4-5 190-00140-02 rev q 4.2 power, lighting, and antennas 4.2.1 power, lighting, and antennas function the section covers the power input requirements, lighting bus input, and antenna connections. 4.2.2 power, lighting, and antennas electrical characteristics 4.2.2...

  • Page 34

    Page 4-6 400 series installation manual rev q 190-00140-02 4.2.3 power, lighting, and antennas configuration refer to section 5.2.6 for lighting configuration. 4.2.4 power, lighting, and antennas calibration and checkout refer to section 3.9 for the com antenna checkout. 4.2.5 power, lighting, and a...

  • Page 35

    400 series installation manual page 4-7 190-00140-02 rev q 4.4 main indicator 4.4.1 main indicator function the main indicator displays both lateral and vertical deviation from selected course, to/from indications, lateral and vertical flags and superflags. The “cdi” key on the bezel of the gns 430 ...

  • Page 36

    Page 4-8 400 series installation manual rev q 190-00140-02 4.4.2.4 superflags pin name connector pin i/o main lateral superflag p4001 17 out main vertical superflag p4001 18 out the superflag outputs supplies not less than 500 ma on a 28 volt system and 250 ma on a 14 volt system with the output vol...

  • Page 37

    400 series installation manual page 4-9 190-00140-02 rev q 4.5 annunciators/switches 4.5.1 annunciators/switches function note initial certification of the 400 series units was accomplished without use of any remote switches or annunciators, since the same switching and annunciation is available on ...

  • Page 38

    Page 4-10 400 series installation manual rev q 190-00140-02 4.5.1.11 integrity annunciate the integrity annunciator illuminates when the gps receiver detects a position error, or is unable to calculate the integrity of the position. 4.5.1.11.1 ils/gps approach output the ils/gps approach output sink...

  • Page 39

    400 series installation manual page 4-11 190-00140-02 rev q 4.6 serial data 4.6.1 serial data function 4.6.1.1 rs-232 the 400 series unit is capable of interfacing with other aviation instruments by transmitting rs-232 type 1 (often known as arnav format) and type 2 (often known as northstar format)...

  • Page 40

    Page 4-12 400 series installation manual rev q 190-00140-02 label # parameter name 1 2 3 4 125 greenwich mean time (bcd) Ɣ Ɣ Ɣ Ɣ 147g magnetic variation Ɣ Ɣ Ɣ 251 distance to go Ɣ 251g distance to go Ɣ Ɣ Ɣ 252 time to go Ɣ Ɣ Ɣ Ɣ 260g date (bcd) Ɣ Ɣ Ɣ 261g gps discrete word 1 Ɣ Ɣ Ɣ 275g lrn status wo...

  • Page 41

    400 series installation manual page 4-13 190-00140-02 rev q 4.6.2 serial data electrical characteristics 4.6.2.1 rs-232 pin name connector pin i/o gps rs 232 out 1 p4001 56 out gps rs 232 in 1 p4001 57 in gps rs 232 out 2 p4001 58 out gps rs 232 in 2 p4001 59 in gps rs 232 out 3 p4001 41 out gps rs ...

  • Page 42

    Page 4-14 400 series installation manual rev q 190-00140-02 4.7 com/vor/ils audio (gnc 420 and gns 430 only) 4.7.1 com/vor/ils audio function and emergency mode activation of com mic key enables com mic audio and causes the transceiver to transmit. 500 : com audio and 500 : vor/ils audio are 100 mw ...

  • Page 43

    400 series installation manual page 4-15 190-00140-02 rev q 4.7.2.3 com audio, vor/ils audio pin name connector pin i/o 500 : com audio hi p4002 7 out 500 : com audio lo p4002 19 out 500 : vor/ils audio hi p4006 16 out 500 : vor/ils audio lo p4006 17 out 500 : com audio and 500 : vor/ils audio each ...

  • Page 44

    Page 4-16 400 series installation manual rev q 190-00140-02 4.8 vor/ils indicator (gns 430 only) 4.8.1 vor/ils indicator function note because the gns 430 includes a “cdi” button that performs switching between gps and vor/ils on a remote indicator, it is seldom necessary to use these outputs to dri...

  • Page 45

    400 series installation manual page 4-17 190-00140-02 rev q 4.8.2.4 flag pin name connector pin i/o vor/loc +flag p4006 3 out vor/loc -flag (vor/loc common) p4006 4 out glideslope +flag p4006 30 out glideslope +down/-flag (glideslope common) p4006 31 out the flag output is capable of driving up to t...

  • Page 46

    Page 4-18 400 series installation manual rev q 190-00140-02 4.9 rmi/obi 4.9.1 rmi/obi function the main obi output provides bearing information from the active waypoint for bendix/king serial obi devices based upon the 400 series unit’s gps navigation. For the gns 430, the main obi output may be con...

  • Page 47

    400 series installation manual page 4-19 190-00140-02 rev q 4.10 dme tuning (gns 430 only) 4.10.1 dme tuning function the gns 430 can channel a dme based on the tuned vloc frequency. The gns 430 outputs 2 of 5, bcd or slip parallel dme and king serial dme channeling format. When dme common is held l...

  • Page 48

    Page 4-20 400 series installation manual rev q 190-00140-02 4.10.3 dme tuning configuration refer to section 5.2.12 for the dme tuning configuration. 4.10.4 dme tuning calibration and checkout none. 4.10.5 dme tuning interconnect refer to figure f-31 on page f-63 for the king serial panel dme tuning...

  • Page 49

    400 series installation manual page 4-21 190-00140-02 rev q 4.11 terrain terrain awareness and warning system (taws) is meant to provide the flight crews with both aural and visual alerts to aid in preventing an inadvertent controlled flight into terrain (cfit) event. While the 400 series unit canno...

  • Page 50

    Page 4-22 400 series installation manual rev q 190-00140-02 4.11.1 terrain configuration refer to section 5.2.3 for terrain configuration. 4.11.2 terrain calibration and checkout refer to section 5.3.10 for terrain checkout procedure. 4.11.3 terrain interface 400 series terrain functionality does no...

  • Page 51

    400 series installation manual page 5-1 190-00140-02 rev q 5. Post installation configuration & checkout procedure 5.1 configuration mode operations with power applied to the aviation rack and the 400 series unit turned off, press and hold the ent key and turn the unit on. Release the ent key when t...

  • Page 52

    Page 5-2 400 series installation manual rev q 190-00140-02 data in 1, data in 2 selection description off no unit connected to this arinc 429 input airdata altitude, temperature, and speed information from the following airdata systems: b & d 2600, 2601, 2800, 90004-003, bendix/king kad 280/480, sha...

  • Page 53

    400 series installation manual page 5-3 190-00140-02 rev q data out selection description off no unit(s) connected to arinc 429 output arinc 429 standard arinc 429 output data (non-gama). Gama 429 arinc 429 data as defined by the general aviation manufacturers’ association (gama) general aviation su...

  • Page 54

    Page 5-4 400 series installation manual rev q 190-00140-02 channel inputs selection description off no unit(s) connected to input of this channel. Arnav/ei-fuel serial fuel flow information from the following units: arnav fc-10, ft-10 electronics international fp-5l crossfill serial transfer of flig...

  • Page 55

    400 series installation manual page 5-5 190-00140-02 rev q 5.2.3 main system config page select the main system config page (see figure 5- 3). This page allows you to configure the fuel and terrain options. Fuel select fuel in the configure field to select the fuel type ( av gas, jet a, or jet b) se...

  • Page 56

    Page 5-6 400 series installation manual rev q 190-00140-02 5.2.4 main inputs 1 page select the main inputs 1 page (see figure 5-5). This page (along with the main inputs 2 page) allows you to monitor the data on arinc 429, rs-232 and other electrical inputs. This is used for verifying electrical int...

  • Page 57

    400 series installation manual page 5-7 190-00140-02 rev q 5.2.6 main lighting page select the main lighting page (see figure 5-8). This page allows you to set display parameters that affect the display backlight and key lighting brightness. The display and key lighting characteristics are adjusted ...

  • Page 58

    Page 5-8 400 series installation manual rev q 190-00140-02 offset adjusts the lighting level up or down for any given input level. This field has a range of 0 (zero) to 99, and is set to 50 at the factory. This may also be used to match lighting curves with other equipment in the panel. Photo trans ...

  • Page 59

    400 series installation manual page 5-9 190-00140-02 rev q external switch state selection verify that: rmt cdi the box is filled in while a remote cdi source select switch is pressed. Rmt obs the box is filled in while a remote obs switch is pressed. 5.2.9 main discrete outputs page select the main...

  • Page 60

    Page 5-10 400 series installation manual rev q 190-00140-02 nav flag (lat/vert) selection verify that: hidden the lat/vert flag is hidden. In view the lat/vert flag is in view. To-from selection verify that: from the from flag is in view. Hidden the to/from flag is hidden. To the to flag is in view....

  • Page 61

    400 series installation manual page 5-11 190-00140-02 rev q obi source (gns 430 only) selection description always gps the main king serial obi outputs are always gps. This is useful if it is desired to switch a bendix/king ki 229 or kni 582 rmi pointer independently from the gns 430 cdi button. Tra...

  • Page 62

    Page 5-12 400 series installation manual rev q 190-00140-02 5.2.11 com setup page (gnc 420 and gns 430 only) select the com setup page (see figure 5-15). These values are set at the factory and seldom require calibration. Freq selects a vhf communication frequency. For purposes of setting the squelc...

  • Page 63

    400 series installation manual page 5-13 190-00140-02 rev q 5.2.12 vor discrete inputs page (gns 430 only) select the vor discrete inputs page (see figure 5- 16). This page allows you to verify the operation of an external vloc transfer switch that may be present in the installation. Selection verif...

  • Page 64

    Page 5-14 400 series installation manual rev q 190-00140-02 to-fr selection verify that: from the from flag is in view. Hide the to/from flag is hidden. To the to flag is in view. Selected course select 150° on the cdi/hsi that is connected to the 400 series vor/loc/gs obs inputs. The selected cours...

  • Page 65

    400 series installation manual page 5-15 190-00140-02 rev q dme mode selection description directed freq 1 if the gns 430 is connected to a multi-channel arinc 429 dme, channel 1 of that dme is tuned. “directed freq 1” should be selected if a single- channel arinc 429 dme is tuned. Directed freq 2 i...

  • Page 66

    Page 5-16 400 series installation manual rev q 190-00140-02 5.2.18 traffic page (only if 400 series unit is configured for bfg skywatch or ryan tcad interfaces) select the traffic page (see figure 5-22). This page shows the bfg skywatch or ryan tcad modes of operation and current traffic situation. ...

  • Page 67

    400 series installation manual page 5-17 190-00140-02 rev q 5.2.21 monitoring the data link the data link is monitored on the data link page. There are four main page groups in the 400 series software version 2.25 or higher: nav, wpt, aux, and nrst (see the 400 series unit pilot’s guide for detailed...

  • Page 68

    Page 5-18 400 series installation manual rev q 190-00140-02 5.3 additional ground tests 5.3.1 connector engagement test 1. Turn on the 400 series unit, and turn on the avionics master switch (if applicable). 2. Place the 400 series unit in the rack and engage the pawl mechanism. 3. Turn the allen sc...

  • Page 69

    400 series installation manual page 5-19 190-00140-02 rev q 5.3.4 deviation & flags check 5.3.4.1 analog deviation & flags the analog deviation (left/right and up/down), to/from, and flag (lateral and vertical) outputs to a cdi or hsi should be verified in flight with potential sources of electrical...

  • Page 70

    Page 5-20 400 series installation manual rev q 190-00140-02 5.3.7 vhf com check (gnc 420 and gns 430 only) a flight test is recommended after the installation is complete to ensure satisfactory performance. To check the communications transceiver, maintain an appropriate altitude and contact a groun...

  • Page 71

    400 series installation manual page a-1 190-00140-02 rev q appendix a. Certification documents a.1 continued airworthiness this section provides assistance to the installing agency in preparing instructions for continued airworthiness (ica) in response to bulletin number hbaw 98-18, “checklist for i...

  • Page 72

    Page a-2 400 series installation manual rev q 190-00140-02 6. Troubleshooting information refer to the 400 series maintenance manual. 7. Removal and replacement information refer to section 3.8 of this manual. If the unit is removed and reinstalled, a functional check of the equipment should be cond...

  • Page 73

    400 series installation manual page a-3 190-00140-02 rev q 19. Terrain database refer to the “400/500 series garmin optional displays pilot’s guide addendum” for terrain database update, regionalization, and status information..

  • Page 74

    Page a-4 400 series installation manual rev q 190-00140-02 a.2 environmental qualification form—gns 430 nomenclature: gns 430 airborne gps/vor/ils/com system type/model/part no.: 010-00139-(), which includes 011-00280-00 tso/jtso compliance: tso-c129a class a (1) (gps) tso-c37d class 4 & 6, jtso-2c3...

  • Page 75

    400 series installation manual page a-5 190-00140-02 rev q a.3 environmental qualification form—gnc 420 nomenclature: gnc 420 airborne gps/com system type/model/part no.: 010-00173-(), which includes 011-00506-00 tso/jtso compliance: tso-c129a class a (1) (gps) tso-c37d class 4 & 6, jtso-2c37e (com ...

  • Page 76

    Page a-6 400 series installation manual rev q 190-00140-02 a.4 environmental qualification form—gps 400 nomenclature: gps 400 airborne gps system type/model/part no.: 010-00171-(), which includes 011-00504-00 tso/jtso compliance: tso-c129a class a (1) (gps) manufacturer’s specification and/or other ...

  • Page 77

    400 series installation manual page a-7 190-00140-02 rev q a.5 environmental qualification form—ga 56 nomenclature: ga 56, gps aviation antenna type/model/part no.: 011-00134-00 (stud mount) 011-00147-00 (flange mount) tso compliance: c129 class a (1) manufacturer’s specification and/or other applic...

  • Page 78

    Page a-8 400 series installation manual rev q 190-00140-02 this page intentionally left blank.

  • Page 79

    400 series installation manual page b-1 190-00140-02 rev q appendix b. Stc permission consistent with n8110.69 or order 8110.4, aviation authority approved installers are hereby granted permission to use stc’s #sa00705wi (gns 430 and gns 430a), #sa00801wi (gnc 420 and gnc 420a), and #sa00800wi (gps ...

  • Page 80

    Page b-2 400 series installation manual rev q 190-00140-02.

  • Page 81

    400 series installation manual page b-3 190-00140-02 rev q.

  • Page 82

    Page b-4 400 series installation manual rev q 190-00140-02.

  • Page 83

    400 series installation manual page b-5 190-00140-02 rev q.

  • Page 84

    Page b-6 400 series installation manual rev q 190-00140-02.

  • Page 85

    400 series installation manual page b-7 190-00140-02 rev q.

  • Page 86

    Page b-8 400 series installation manual rev q 190-00140-02.

  • Page 87

    400 series installation manual page b-9 190-00140-02 rev q.

  • Page 88

    Page b-10 400 series installation manual rev q 190-00140-02 this page intentionally left blank..

  • Page 89

    400 series installation manual page c-1 190-00140-02 rev q appendix c. 400 series rs-232 aviation data format c.1 electrical interface the output signals shall be compatible with rs-232c. Data shall be generated at 9600 baud with a word length of 8 bits, one stop bit, and no parity. C.2 general outp...

  • Page 90

    Page c-2 400 series installation manual rev q 190-00140-02 the following table describes the type 1 output sentence item designator (id) and item data (dddd) fields. If data for these sentences is invalid or unavailable, dashes ("-") are used to fill in all non-blank character positions. * the line ...

  • Page 91

    400 series installation manual page c-3 190-00140-02 rev q c.4 output sentence type 2 the 400 series type 2 output sentence shall have the following general format: id - item designator (3 ascii characters) seq - sequence number (1 binary byte) wpt - waypoint identifier (5 ascii characters) lat - wa...

  • Page 92

    Page c-4 400 series installation manual rev q 190-00140-02 the following table describes the type 2 output sentence item designator (id), sequence number (seq), waypoint identifier (wpt), waypoint latitude (lat), waypoint longitude (lon), and magnetic variation at waypoint (mvar) fields. Field byte ...

  • Page 93

    400 series installation manual page d-1 190-00140-02 rev q appendix d. 400 series rs-232 fuel/air data input format d.1 electrical interface the input signals shall be compatible with rs-232c. Data shall be input at 9600 baud with a word length of 8 bits, one stop bit, and no parity. One message is ...

  • Page 94

    Page d-2 400 series installation manual rev q 190-00140-02 d.4 shadin fuel flow sentence the garmin 400 series units shall be capable of receiving the following 55-byte message from the shadin fuel flow indicator: k0543.20100.00040.00060.00123.40045.40078.0123 where: start-transmit character (0x02) ...

  • Page 95

    400 series installation manual page d-3 190-00140-02 rev q d.6 shadin fuel/airdata computer sentence the garmin 400 series units shall be capable of receiving the following message strings from the shadin fuel/airdata or airdata computer: d.6.1 shadin “z” format za012 "za" (ascii characters); "012" ...

  • Page 96

    Page d-4 400 series installation manual rev q 190-00140-02 d.6.2 shadin “g” format ga012 "ga" (ascii characters); "012" represents indicated air speed (knots) gb345 "gb" (ascii characters); "345" represents true air speed (knots) gc678 "gc" (ascii characters); "678" represents mach speed (thousandth...

  • Page 97

    400 series installation manual page d-5 190-00140-02 rev q d.6.3 shadin “s” format sa012 "sa" (ascii characters); "012" represents indicated air speed (knots) sb345 "sb" (ascii characters); "345" represents true air speed (knots) sc678 "sc" (ascii characters); "678" represents mach speed (thousandth...

  • Page 98

    Page d-6 400 series installation manual rev q 190-00140-02 where: start-transmit character (0x02) carriage-return character (0x0d) line-feed character (0x0a) sign indicator (0x2b["+"] or 0x2d["-"]) end-transmit character (0x03) note: checksum is calculated by adding each byte in the message (includi...

  • Page 99

    400 series installation manual page e-1 190-00140-02 rev q appendix e. 400 series lru interface overview the following tables provide a quick overview of some of the equipment that can be interfaced with the garmin 400 series units. This is not a complete listing however; it only represents those un...

  • Page 100

    Page e-2 400 series installation manual rev q 190-00140-02 function bendix/king collins efis efis 40/50 efis-84 displays sg 465 dpu-84 function sandel ehsi sn 3308 function bendix/king collins honeywell litef litton iru/ahrs kau 461 ahc 85e laseref ltr 81 ltn 90-100 hg 1075 ab ltn-91 hg 1095 ab ltn-...

  • Page 101

    400 series installation manual page f-1 190-00140-02 rev. Q appendix f. Drawings and interconnects f.1 introduction this section contains installation drawings to aid in the installation of a 400 series unit. Additional information and notes included on the drawings can be used as reference informat...

  • Page 102

    Page f-2 400 series installation manual rev. Q 190-00140-02 figure f-29—vor/ils indicator interconnect figure f-30—rmi/obi interconnect figure f-31—king serial panel dme tuning interconnect figure f-32—king serial remote dme tuning interconnect figure f-33—parallel 2 of 5 dme tuning interconnect fig...

  • Page 103

    400 series installation manual page f-3 (page f-4 blank) 190-00140-02 rev q figure f-1. Ga 56 antenna installation draw ing.

  • Page 104

    400 series installation manual page f-5 (page f-6 blank) 190-00140-02 rev q figure f-2. Gns 430 mounting rack dimensions.

  • Page 105

    400 series installation manual page f-7 (page f-8 blank) 190-00140-02 rev q figure f-3. Gnc 420 mounting rack dimensions.

  • Page 106

    400 series installation manual page f-9 (page f-10 blank) 190-00140-02 rev q figure f-4. Gps 400 mounting rack dimensions.

  • Page 107

    400 series installation manual page f-11 (page f-12 blank) 190-00140-02 rev q figure f-5. Gns 430 mounting rack installation.

  • Page 108

    400 series installation manual page f-13 (page f-14 blank) 190-00140-02 rev q figure f-6. Gnc 420 mounting rack installation.

  • Page 109

    400 series installation manual page f-15 (page f-16 blank) 190-00140-02 rev q figure f-7. Gps 400 mounting rack installation.

  • Page 110

    400 series installation manual page f-17 (page f-18 blank) 190-00140-02 rev q figure f-8. 400 series recommended panel cutout dimensions.

  • Page 111

    400 series installation manual page f-19 (page f-20 blank) 190-00140-02 rev q figure f-9. 400 series sy stem interface diagram.

  • Page 112

    400 series installation manual page f-21 (page f-22 blank) 190-00140-02 rev q figure f-10. Gns 430 ty pical installation.

  • Page 113

    400 series installation manual page f-23 (page f-24 blank) 190-00140-02 rev q figure f-11. Gnc 420 ty pical installation.

  • Page 114

    400 series installation manual page f-25 (page f-26 blank) 190-00140-02 rev q figure f-12. Gps 400 ty pical installation.

  • Page 115

    400 series installation manual page f-27 (page f-28 blank) 190-00140-02 rev q figure f-13. Pow er, lighting, and antenna interconnect.

  • Page 116

    400 series installation manual page f-29 (page f-30 blank) 190-00140-02 rev q figure f-14. Altimeter interconnect.

  • Page 117

    400 series installation manual page f-31 (page f-32 blank) 190-00140-02 rev q figure f-15. Main indicator interconnect.

  • Page 118

    400 series installation manual page f-33 (page f-34 blank) 190-00140-02 rev q figure f-16. Ki 209a main indicator interconnect.

  • Page 119

    400 series installation manual page f-35 (page f-36 blank) 190-00140-02 rev q figure f-17. Ki 208a main indicator interconnect.

  • Page 120

    400 series installation manual page f-37 (page f-38 blank) 190-00140-02 rev q figure f-18. Annunciators/sw itches interconnect.

  • Page 121

    400 series installation manual page f-39 (page f-40 blank) 190-00140-02 rev q figure f-19. Rs-232 serial data interconnect.

  • Page 122

    400 series installation manual page f-41 (page f-42 blank) 190-00140-02 rev q figure f-20. Arinc 429 efis interconnect.

  • Page 123

    400 series installation manual page f-43 (page f-44 blank) 190-00140-02 rev q figure f-21. Arinc 429 sandel ehsi interconnect (1 400 series unit, 1 sandel sn3308).

  • Page 124

    400 series installation manual page f-45 (page f-46 blank) 190-00140-02 rev q figure f-22. Arinc 429 sandel ehsi interconnect (2 gns 430, 1 sandel sn3308).

  • Page 125

    400 series installation manual page f-47 (page f-48 blank) 190-00140-02 rev q figure f-23. Arinc 429 sandel ehsi interconnect (2 gns 430, 2 sandel sn3308).

  • Page 126

    400 series installation manual page f-49 (page f-50 blank) 190-00140-02 rev q figure f-24. Arinc 429/rs-232 air data/iru/ahrs interconnect.

  • Page 127

    400 series installation manual page f-51 (page f-52 blank) 190-00140-02 rev q figure f-25. Arinc 429 flight control interconnect.

  • Page 128

    400 series installation manual page f-53 (page f-54 blank) 190-00140-02 rev q figure f-26. Traffic advisory sy stem interconnect.

  • Page 129

    400 series installation manual page f-55 (page f-56 blank) 190-00140-02 rev q figure f-27. Weather and terrain interconnect.

  • Page 130

    400 series installation manual page f-57 (page f-58 blank) 190-00140-02 rev q figure f-28. Audio panel interconnect.

  • Page 131

    400 series installation manual page f-59 (page f-60 blank) 190-00140-02 rev q figure f-29. Vor/ils indicator interconnect.

  • Page 132

    400 series installation manual page f-61 (page f-62 blank) 190-00140-02 rev q figure f-30. Rmi/obi interconnect.

  • Page 133

    400 series installation manual page f-63 (page f-64 blank) 190-00140-02 rev q figure f-31. King serial panel dme tuning interconnect.

  • Page 134

    400 series installation manual page f-65 (page f-66 blank) 190-00140-02 rev q figure f-32. King serial remote dme tuning interconnect.

  • Page 135

    400 series installation manual page f-67 (page f-68 blank) 190-00140-02 rev q figure f-33. Parallel 2 of 5 dme tuning interconnect.

  • Page 136

    400 series installation manual page f-69 (page f-70 blank) 190-00140-02 rev q figure f-34. Parallel bcd/slip code dme tuning interconnect.