Golmar Stadio Plus Instruction Manual - page 35
109
OPTIONAL CONNECTIONS
ock releases connection.
L
d.c. lock release
a.c. lock release
SEC
~
~
~
~
PRI
TF-104
Main
CV2
CV1
+12
CN1
-
Doorpanel
CV2
CV1
+12
CN1
-
Doorpanel
A d.c. lock release is supplied together with the doorpanel, however, it´s possible to connect
also an a.c. lock release. For this option, an additional TF-104 transformer is needed.
ink of several power supplies units.
L
If the quantity of monitors or telephones to be connected is bigger than the supported
from one power supply (see page 94), use additional power supplies to match the
required quantity. The first power supply should be connected to the door panel and
to the first group of monitors or telephones; connect the next groups to the positive
terminal of its corresponding power supply.
To wire several power supplies link their ground terminals;
NEVER link positive terminals of different power supplies.
To the door panel and to
the first group of monitors
or telephones.
To the second group of
monitors or telephones.
1st FA-Plus
2nd FA-Plus or FA-Plus/C
SEC
PRI
~
~
Main
+ +
-
-
SEC
PRI
~
~
Main
+ +
-
-
The lock release can be activated at any moment by using an external push button, that must
be connected between 'CV1' and 'CV2' terminals, as shown in the diagram.
This function will allow to exit from the building being not necessary the use of a key.
FA-PLUS or FA-PLUS/C rev. 938072.
*
*
110
OPTIONAL CONNECTIONS
A
_
+
D
Malla
V
in
V
out
CN4
onnecting the Platea Plus monitor to a video recorder or TV.
C
If your TV or video recorder have a SCART
connector, it will be possible to view
the picture from the door panel on the TV
screen.
Remove the end of line jumper and connect the coaxial
cable between terminals 17 (shield) and 20 (hot)
of the SCART connector.
Only available for Coaxial installations.
ntercom function.
I
Platea Plus monitor and T-940 Plus telephone have intercom facility between two units of the
same apartment. To enable this function check the following conditions:
- One of the units has been configurated as master and the other unit as slave with
intercom, as described on pages 100 to 106.
In case to intercom one monitor with one telephone, configure the monitor as master.
- Link the INT terminal of the units, as it is shown on the enclosed diagram.
To establish an intercom communication lift the handset and press the intercom push button;
acoustic tones will be reproduced on the handset confirming the call is in progress or
that the other unit is communicating with the door panel. To establish communication lift
the handset of the called unit
. If during an intercom
communication a call is made from the
door panel, acoustic tones will be heard
on the master unit handset and the picture
will appear in case of a monitor;
press the intercom push button of the
master unit to establish communication
with the door panel, or press the door
release push button to activate the lock
release.
The reproduced acoustic tones are different
depending on their provenance, that allows the
user to distinguish where the call is made from.
A
+ _
D INT
A
_
+
D
INT
Malla
V
in
V
out
CN4
HZ-
-
oor bell push button connection.
D
The monitors and telephones can be used to receive the calls made from the apartment door,
saving the use of a bell. Wire the push button of the apartment door to the 'HZ ' and ' '
monitor or telephone terminals.
The reproduced acoustic tones are different depending on their
provenance, that allows the user to distinguish where the call
is made from. If during a conversation a call is made from
the apartment door, acoustic tones will be reproduced on the
hanset to advise that someone is calling.
–
–