Haier AB092FCBHA User Manual - Procedures
17
Liquid pipe
Gas pipe
1
2
1
2
Flaring dimensions
Diameter
6.35mm(1/4")
9.52mm(3/8")
12.7mm(1/2")
15.88mm(5/8")
Dimensions
A(mm)
0.8-1.5
1.0-1.8
1.0-2.0
1.4-2.2
Correct
Tilt Broken
Incomplete Overflared
Burrs
Caution: Electrical engineering must be carried out by qualified electrician and copper core
cables must be used for all wiring systems.
1.Cutting
3.Applying
screw nut
2.Removing burrs
Electric wiring
4.Flaring
Expander
A
For Indoor Unit
Incorrect
l
Firm and free from vibration
l
Open and away from heat and steam sources
l
Convenient for water drainage and connection to the heat pump
l
Favorable for airflow spread
l
Accessible to power source with required space around the appliance
l
Free from TV sets, radio, cordless appliance and at least 1 meter
away from the light
l
Convenient for receiving signals from remote controller fixed on the
wall with the light on
l
Outdoor unit at least 2.5 meters high above the floor in a room
adjacent to traffic
Pipe cutting and flaring
Cutting and flaring should be carried out for the pipes with excessive length or damage
on the flared section.
Location
Procedures
Gas pipe
Liquid pipe