Home Automation 12A00 Installation Manual - page 9
7
RESET MEMORY
To erase all transmitters from memory and to reset to the factory default configuration, press and
hold both the Set and Mode/Advance switches simultaneously for 2 seconds. You are first
prompted to enter a code (as mentioned above). After the code is entered, the display will show
"EE". If you choose to continue, press and hold the Set and Mode/Advance switches
simultaneously for 2 seconds once again. Memory is reset at the end of the two seconds.
NOTE: If you choose not to reset memory at the "EE" display, don’t press any keys for a 10
second period and the receiver will return to Run mode.
CONNECTING TO OMNILT
Connect the "A" and "B" terminals of the 12A00 to the OmniLT (Yellow = A and Green = B).
Connect the "+12" and "GND" terminals of the 12A00 to the "AUX 12V" and "AUX GND"
terminals the OmniLT, respectively.
OmniLT Controller
12A00 Wireless Receiver
OMNILT SETUP
A. On the console, enter the "Installer Setup" menu (press 9, installer code, then #). Press 2 for
“Zones”, then press 1 # (“Wireless Receiver?” Yes = 1).
B. When connected to OmniLT, zones 9-24 are the wireless receiver zones.
C. When connected to OmniLT, the receiver address on the 12A00 must be set to "A1" and the
number of addresses must be set to "n1".
D. OmniLT can handle up to 4 transmitters per zone.