VPN Subnets Tab
The local and remote subnet for the VPN tunnel and should be CIDRS, for example:
172.16.0.0/12
10.0.0.0/8
Advanced VPN Settings Tab
Normally use can choose the “auto” option for all the settings on this page. However if the VPN does not
form then you may need to specify the Phase 1 and/or Phase 2 parameters. E.g. The encryption type
(AES/DES), the hashing algorithm (MD5/SHA) and the Diffe-Hellman group.