I-MO 520 Series Product Installation Manual - page 44
Manual is about: Bonding Router
of
58
INSTALLATION MANUAL FOR THE EMS I-MO 540 SERIES APPLIANCE
Version
1.2
ELECTRONIC MEDIA SERVICES LIMITED
PASSFIELD BUSINESS CENTRE, LYNCHBOROUGH ROAD, LIPHOOK, HAMPSHIRE, GU30 7SB, UK
Tel: 01428 751655 | Fax: 01428 751654 | E-mail: imo@ems-uk.com
Page
44
of
58
mob0heartbeatperiod="50"
# If heartbeat address is unavailable for
# “heartbeatperiod” seconds it will be
# marked as down
mob0hearbeataddress="8.8.4.4" # The address of the heartbeat device
# This address must respond to ICMP pings
[vpn]
enabled="no"
# VPN disabled
[fw]
enabled="yes"
# Enable the firewall
masq="yes"
# Enable masquerading (NAT)
masqnets="0/0"
# Masquerade all traffic sent to external zone
[nas]
enabled="yes"
# Enable the NAS server