Intermec Janus 2020 Reference Manual - Im_Get_Label_Symbology
im_get_label_symbology
3-33
3
im_get_label_symbology
Purpose:
This function retrieves the symbology, such as Code 39, from the most
recently scanned label. Call this function after receiving the data using
im_receive_input.
Syntax:
With Intrmecd_IO, Intrmecp_IO;
Use Intrmecd_IO, Intrmecp_IO;
procedure im_get_label_symbology (
symbology : OUT IM_DECTYPE;
status_code : OUT System.Word);
IN Parameter:
None.
OUT Parameter:
The symbology parameter is one of the following constants:
IM_CODE_11
Code 11 bar code
IM_CODE_16K
Code 16K bar code
IM_CODE_39
Code 39 bar code
IM_CODE_49
Code 49 bar code
IM_CODE_93
Code 93 bar code
IM_CODE_128
Code 128 bar code
IM_CODABAR
Codabar bar code
IM_I_2_of_5
Interleaved 2 of 5
IM_MSI
MSI bar code
IM_PLESSEY
Plessey bar code
IM_UNKNOWN_DECODE
Unknown bar code
IM_UPC
Universal Product Code
The status_code is one of the standard status codes defined in Appendix A,
“Status Codes.”
Return Value:
None.
Notes:
You must install the Reader Wedge to use this function. For information on
loading RWTSR.EXE, see “Runtime Requirements” in Chapter 2, “Working
With Ada.”
See Also:
im_receive_input