Jablotron JA-63 „PROFI“ User Manual - page 10
Alarm system JA-63 „Profi“
- 10 -
MGK51504
Actions' table
a
no splitting
split
0
no action
no action
1
arm all
arm all
2 disarm disarm
all
3 partial arming
arm A
4 partial arming
arm B
5 disarm disarm
A
6 disarm disarm
B
4.4 Automatic arming / disarming
The system can automatically arm and disarm for a requested period of a day.
While in the user more, up to ten instructions (time & action) can be programmed
in the period of one day.
To switch the control panel to the user mode enter F 0 master code. User
mode will be indicated by a U on the keypad. To program automatic arming enter:
64 n a hh mm
where: n = instruction number from 0 to 9
a = action (see the actions' table)
hh = hours (from 00 to 23)
mm = minutes (from 00 to 59)
Example: to program an automatic complete
arming of the system at 21:15 everyday
enter: 64 0 1 21 15
Notes:
If any automatic action is selected, it will be preformed everyday at the
programmed time, following the internal control panel clock.
The automatic arming and disarming can be overridden manually anytime
(by a user code or a remote control)
If the control panel is in the requested arming mode before the action
time, the programmed action will not change the arming
Factory default setting - all instructions are set for no action
To exit user mode, press the N key.
4.5 Bypass
The supervisor can bypass (switch off) particular zones (potential sources of
alarms) while in the user mode. If a zone is bypassed, it can’t trigger an alarm.
To switch the control panel to the user mode enter F 0 master code. User
mode will be indicated by a U on the keypad.
To set up bypass:
1. Press
key
1 to open the bypass menu.
2. With key 1 and 7 you can scroll all potential alarm sources (wireless
detectors are distinguished with the symbol
).
3. Select the source (detector, wired input…) which you want to bypass and:
a. either press key 2 for 2 seconds to bypass the source for the next
arming period (confirmed by flashing Battery LED);
b. or press key 3 for 2 seconds to bypass the source permanently
(confirmed by the Battery LED being permanently lit);