    Ja-63 „profi“ alarm system - 3 - mgk55401 contents: 1 architecture of the control panel ................................................................................................................................4 2 control panel installation.........................................................

  • Page 4

    Ja-63 „profi“ alarm system - 4 - mgk55401 this product should be installed by professional installers. The manufacturer assumes no liability for damages caused by incorrect installation or improper use of this system. 1 architecture of the control panel the ja-63 "profi" is a fully programmable cont...

  • Page 5

    Ja-63 „profi“ alarm system - 5 - mgk55401 2.1 mains supply connection it is specified to connect the control panel by a permanent two- wire cable. The power supply has a double isolation. The ground wire is unattached. • an inlet is realized by a permanent two-wire cable with a double isolation – wi...

  • Page 6

    Ja-63 „profi“ alarm system - 6 - mgk55401 (during an alarm, the charging will temporarily halt). The siren can also be used for arming and disarming chirps and as an audible indicator while in the testing mode (see section 10). Pgx, pgy are outputs (switching to gnd when activated, max. 12v, 100ma)....

  • Page 7

    Ja-63 „profi“ alarm system - 7 - mgk55401 5 the ja-60 keypad(s) the system can be programmed and operated by ja-60e keypad(s). As a maximum, 4 keypads can be wired to the control panel. The keypads can either be wired by cables equipped with modular jacks or by standard cables to terminals 1234. The...

  • Page 8

    Ja-63 „profi“ alarm system - 8 - mgk55401 list of control panel programmable parameters function sequence options factory note enrolling of detectors and controllers 1 1& 7 scroll, 2 erases item - r module hard-wired zone input setting 60 nn xys nn - zone, x - triggering, y - reaction, s - section l...

  • Page 9

    Ja-63 „profi“ alarm system - 9 - mgk55401 9.1 enrollment (teaching) of wireless items enter: 1 the control panel equipped with a radio module can enroll up to 32 wireless detectors (2 in each zone), up to 8 controllers (remote controls & keypads), wireless sirens and an additional ja-6x control pane...

  • Page 10

    Ja-63 „profi“ alarm system - 10 - mgk55401 9.3 exit delay sequence: 2 0 x to change the duration of the exit delay enter: 20x (where x represents time in seconds x10). The delay can be selected from 10 to 90 seconds. Example: to select an exit delay duration of 20 seconds, enter 202 factory default ...

  • Page 11

    Ja-63 „profi“ alarm system - 11 - mgk55401 9.10 reset enabled sequence: 2 8 x the factory default reset (see 11) can be disabled. This way no unauthorized future programming of the control panel will be possible. Options: 2 8 1 reset enabled 2 8 0 reset disabled warning: if the master or service cod...

  • Page 12

    Ja-63 „profi“ alarm system - 12 - mgk55401 9.16 exit delay audible indication sequence: 3 3 x the exit delay can be indicated by the “beeping“ of the keypad (for the last five seconds, the beeping is faster). The audible indication can be disabled with this setting. Options : 3 3 1 indication enable...

  • Page 13

    Ja-63 „profi“ alarm system - 13 - mgk55401 9.24 only first source of alarm is recorded sequence: 691 x when any item triggers the alarm 4 times in a row the system will bypass it until any other events occurs. But it is possible to set the limit at the incoming events so only the very first event du...

  • Page 14

    Ja-63 „profi“ alarm system - 14 - mgk55401 actions' table a no splitting split system 0 no action no action 1 arm all arm all 2 disarm disarm all 3 partial arming arm a 4 partial arming arm b 5 disarm disarm a 6 disarm disarm b where : nn = number of the enrolled controller from 01 to 08 (c1 to c8) ...

  • Page 15

    Ja-63 „profi“ alarm system - 15 - mgk55401 note: this procedure resets the factory default settings (see part 9). The master code will be 1234, service code 6060 and all user codes, wireless detectors & controllers will be forgotten. If there is built-in ja-65x communicator all telephone numbers for...

  • Page 16

    Ja-63 „profi“ alarm system - 16 - mgk55401 13 recommended professional in- staller basic rules if you install the system for a customer, you should follow these rules: • make a drawing of intended location of the items, keeping in mind proper protection for the intended area. • if the customer reque...

  • Page 17

    Ja-63 „profi“ alarm system - 17 - mgk55401 16 control panel specifications: electrical power 230 vac, max 0.1 a, supervised, class ii backup battery 12 v, 1.3 or 2.6 ah, normal life time 5 years backup power output 13vdc, the max. Permanent current is 0.4 or 1a for max. 15 min (1 cycle per hour), se...