Jablotron JA-63 „PROFI“ Installation Manual - page 11
JA-63 „PROFI“ Alarm System
- 11 -
MGK55401
9.10 Reset enabled
sequence: 2 8 x
The factory default reset (see 11) can be disabled. This way
no unauthorized future programming of the control panel will be
possible.
options:
2 8 1 reset
enabled
2 8 0 reset
disabled
Warning: if the Master or Service code is forgotten when the
reset is disabled. The reset of the control panel will be possible
only by the manufacturer.
Factory default setting: reset enabled
9.11
Arming control of a subsystem
sequence: 2 9 0
A wireless master control panel receives event signals
(alarms, tampering, faults, low battery) from a JA-6x subsystem
if enrolled – see 9.1 and 9.12. This will cause the same kind of
event on the master control panel and J will be indicated as the
source of the event on the keypad.
The master and slave control panels can be either armed and
disarmed as two independent systems or the slave system can
follow the arming and disarming of the master. If the master
should rule arming of the slave subsystem, make the following
settings:
a. enroll a subsystem to the master‘s J position (see 9.1 and
9.12),
b. place the master panel into the programming mode (P is
indicated),
c. enter the enrolling mode in the sub-control panel (pressing
key 1 while in the programming mode)
d. enter 290 on the master control panel – this way the
master will enroll to the slave sub-control panel as a
wireless controller (to the first free position of c1 to c8)
e. turn both systems to standby mode and check that the
subsystem will arm after the master control panel is armed
(in 2 seconds). Check the same for disarming
Notes:
•
Master control panel generates wireless commands Arm
and Disarm the same way as a remote control RC-40.
The control panel transmits these commands only if it has
a subsystem enrolled in its position J.
•
The Arm command is generated when the master control
panel is completely armed and also at the end of an alarm
while the system remains completely armed (automatic
alarm timeout). The Disarm command is generated when
the master control panel is disarmed, when it is partly
armed (home arming or one section arming if it is split)
and also in the end of an alarm while the system is
disarmed (manual termination of the alarm).
•
The subsystem can also be operated by its other
controllers (remote controls, keypads) if there are any. For
better understanding you can simply imagine, that the
master control panel is just another remote control.
•
Arming control of the subsystem by the master control
panel can be disabled by erasing the corresponding cN
position in the sub-control panel. For example if the
master control panel was enrolled to position c3, scroll to
this position in the enrolling mode and holding key 2 will
erase the master control panel as a controller.
9.12
Enrollment of the control panel to a UC-2xx or
to a master control panel
sequence: 2 9 9
The wireless control panel can send data to output modules
UC–216, UC–222 and UC-260. It can also work as a subsystem
of another JA-6x.
Enter the enrolling mode of the UC receiving device and then
enter 299 on the control panel. Note that the control panel must
be in the programming mode. This enables the control panel to
generate the enrollment signal.
If you want to enroll a subsystem to your control panel, enter
the enrolling mode on the MASTER control panel (see 9.1) and
then enter sequence 299 in the programming mode of the sub
control panel.
If the system is split, the sub control panel enrolls to the
common shared section.
9.13
No code requested for
,
,
,
(F1,
F2, F3), F4, F8 & F9
sequence: 3 0 x
If this parameter is enabled, no code is requested for the
functions listed above. When this parameter is disabled, these
functions (keys) can be used only when followed by a code
(Master or User) – see the following table:
„code“ = Master or User
Factory default setting: no code requested
Note: this feature is also selectable on the JA-60D wireless
keypad and it is independent from the control panel setting.
9.14
Partial (Home) arming with
- non split
control
panel
sequence: 3 1 x
In partial arming, the control panel reacts only to detectors
addressed to section A (see 9.2 and 9.30) and it ignores the
triggering of detectors in section B or C (except smoke and gas
detectors). Partial arming can be disabled with this sequence.
options
:
3 1 1 partial
arming
enabled
3 1 0 partial arming disabled
Factory default setting: partial arming enabled
9.15
Hard wired siren alarm enabled
sequence: 3 2 x
The SIR siren output is activated when any alarm is triggered
(except silent Panic alarm). This siren indication can be disabled
with this parameter.
options
:
3 2 1 siren
enabled
3 2 0 siren
disabled
Factory default setting: siren enabled
function / setting
301
300
arming
„code“
partial arming
„code“
door opening
„code“
memory reading
F 4
F 4 „code“
appliance control
F80, F81
F8 “code” 0
F8 “code” 1
message
listening
F 9
F 9 „code“