Jablotron JA-63 „PROFI“ Installation Manual - page 8
JA-63 „PROFI“ Alarm System
- 8 -
MGK55401
List of control panel programmable parameters
Function
sequence
options
factory
note
Enrolling of detectors and controllers
1
1& 7 scroll, 2 erases item
-
R module
Hard-wired zone input setting
60 nn xys
nn - zone, x - triggering,
y - reaction, s - section
L1=delay
L2=next d.
L3=instant
L4=tamper
Exit delay
20x
x = 1 to 9 (x 10sec.)
30sec.
Entrance delay
21x
x = 1 to 9 (x 10sec.)
30sec.
Alarm duration
22x
x = 1 to 8 (min.), 0=10s,
9=15min
4min.
Function of PgX output
23x
x = 0 to 8 (0-Chime, 1-Fire,
2-Arm, 3-Panik, 4-Alarm,
5-Door, 6-Home, 7-No AC,
8-By phone)
Chime different
when
split
Function of PgY output
24x
x = 0 to 8 (0-Chime, 1-Fire,
2-Arm, 3-Panik, 4-Alarm,
5-Door, 6-Home, 7-No AC,
8-By phone)
Arm different
when
split
Voice m. & tel. Numbers editable in the user mode
25x
251 = YES 250 = NO
NO
X module
Radio signal jamming regular testing
26x
261 = YES 260 = NO
NO
R module
Regular communication check enabled
27x
271 = YES 270 = NO
NO
R module
RESET enabled
28x
281 = YES 280 = NO
YES
Subsystem arming enrollment
290
will enroll to sub-control panel as wireless
controller
R module
Control panel teaching to a UC-2xx, master-system,...
299
will enroll as control panel
R module
No code requested for
,
,
, F4 & F9
30x
301 = YES 300 = NO
YES
Partial (Home) arming enabled
31x
311 = YES 310 = NO
YES
Siren alarm enabled
32x
321 = YES 320 = NO
YES
Exit delay audible indication enabled
33x
331 = YES 330 = NO
YES
Partial arming exit delay audible indication
34x
341 = YES 340 = NO
NO
Entrance delay audible indication enabled
35x
351 = YES 350 = NO
YES
Arming & disarming chirp sounds enabled
36x
361 = YES 360 = NO
NO
Siren in Disarm & Partial arming enabled
37x
371 = YES 370 = NO
YES
Wireless siren alarm enabled
38x
381 = YES 380 = NO
YES
R module
Indication of system problems when arming
39x
391 = YES 390 = NO
NO
Split control panel (A, B & C sections)
690x
6901 = YES 6900 = N0
NO
Only first source of alarm is recorded
691x
6911 = YES 6910 = NO
NO
Alarm triggered by opened zone when arming
692x
6921 = YES 6920 = NO
NO only
if
391
Audible panic alarm
693x
6931 = YES 6930 = NO
NO
Next delay wireless detectors
694x
6941 = YES 6940 = NO
NO
Communication loss alarm
696x
6961 = YES 6960 = NO
YES
Entering the programming mode by SC+MC/UC
697x
6971 = YES 6970 = NO
NO
Addressing of wireless detectors to sections
61 nns
nn - zone n., s - section
1-10A
11-16B
R module
Addressing of user codes to sections
62 nns
nn - code n., s - section
all A
when split
Addressing of wireless controllers to sections
63 nns
nn - controller n., s - section
all A
R module
Automatic arming / disarming
64nahhmm
N - 0-9, a - action,
hh - hours, mm - min.
all off
Service Code changing
5 nSC nSC
nSC = new Service Code
6060 code
2x
User Mode entering
6999
Goes to the User mode
-
Real time and date setting
4 hh mm DD MM RR
00 00 01 01 00