Jablotron JA-63 „PROFI“ Installation Manual - page 6
JA-63 „PROFI“ Alarm System
- 6 -
MGK55401
(during an alarm, the charging will temporarily halt). The
siren can also be used for arming and disarming chirps
and as an audible indicator while in the testing mode (see
section 10).
PGX, PGY are outputs (switching to GND when activated, max.
12V, 100mA). The function of these outputs are
determined by the setting in the programming mode (see
9.6). The control panel also wirelessly transmits the PGX
and PGY signals and UC receiving units can be used as
remote outputs for these signals.
+U
is a back up power output for external items (detectors
etc.). The max. permanent current is 0.4A (1A for max. 15
min - not more then one cycle per hour). This output is
fused (FU1 1A) and supervised by the control panel. If it is
overloaded, a control panel failure will be indicated (fault
C).
GND
is a common ground terminal for power output (-).
Fig. 1 – Wiring examples