Jenn-Air 30" (76.2 CM) Installation Instructions Manual - Gas Conversions
14
If range does not operate, check the following:
■
Household fuse is intact and tight, or circuit breaker has not
tripped.
■
Range is plugged into a grounded outlet.
■
Electrical supply is connected.
■
See “Troubleshooting” in the Use and Care Guide.
8. When the range has been on for 5 minutes, check for heat. If
the range is cold, turn off the range and check that the gas
supply line shutoff valve is open.
■
If the gas supply line shutoff valve is closed, open it, then
repeat the 5-minute test as outlined above.
■
If the gas supply line shutoff valve is open, close it, and
contact a qualified technician.
If you need Assistance or Service:
Please reference the “Assistance or Service” section of the
Use and Care Guide or contact the dealer from whom you
purchased your range.
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
LP Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Locate gas pressure regulator at the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
2