RS232 Commands
Communication protocol: RS232 Communication Protocol
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
System Command
Command
Description
Command Example and
Response
/*Type;
Report system model.
/*Type;
CE-MX44
/%Lock;
Lock front panel buttons.
/%Lock;
System Locked!
/%Unlock;
Unlock front panel buttons.
/%Unlock;
System UnLock!
/^Version;
Report software version.
/^Version;
V1.0.0
Undo.
Cancel the current operation and return to
previous switching status.
Undo.
Undo Ok!
PWON.
Power on the system.
PWON.
PWON
STANDBY.
Turn the system to standby mode.
STANDBY.
STANDBY
%9961.
Report the system locking status.
%9961.
System UnLock!
System Locked!
%9962.
Report the system power status.
%9962.
PWON
%0911.
Reset to factory default.
%0911.
Factory Default
Signal Switching
Command
Description
Command Example and
Response
[x]All.
Switch input [x] AV to all output. x=1~4.
2All.
02 To All.
All#.
Switch all input signal to the corresponding
output channel.
All#.
All Through.
All$.
Switch off all output.
All$.
All Closed.
[x]#.
Switch input [x] to output [x]. x=1~4.
1#.
01 Through.
[x]$.
Turn off output [x]. x=1~4.
1$.
01 Closed.
[x]@.
Turn on output [x]. x=1~4.
1@.
01 Open.
All@.
Turn on all outputs.
All@.