Summary of KS-258B

  • Page 1

    User’s manual 8-zone telephone alarm system.

  • Page 2

    Table of contents 1.Main functions and characteristics ---------------------------------------------1 2.Operate precautions ----------------------------------------------------------------1 3.Name and usage of main parts ---------------------------------------------------2 4.Diagram of connection --...

  • Page 3

    8-zone telephone alarm system main unit --------------------------------------------------------------13 wireless remote controller -----------------------------------------13 wireless door sensor ------------------------------------------------14 pir detector ---------------------------------------...

  • Page 4

    8-zone telephone alarm system - 1- summary this system adopts microprocessor as control core, and it can work with wireless remote controllers and all kinds of wireless pir detectors. It characteristics of many functions, such as anti-theft, anti-rob, anti-fire, emergency ask for help and so on. It ...

  • Page 5

    8-zone telephone alarm system - 2- hazard class i, ii or iii locations (i.E. Where there have flammable and explosive steam gas, dusts of some certain concentration, otherwise, it will be very dangerous) the backup battery should be aa 1.2v ni-mh rechargeable battery, and one off dry battery is ban...

  • Page 6

    8-zone telephone alarm system - 3- 3.2back components of main unit picture 2 ① city inputting: ac 220v±15%50hz inputting power ② “set” button: enter setting state by pressing and holding this button for 3 seconds, and exit from setting state by pressing and holding this button for 3 seconds. ③ telep...

  • Page 7

    8-zone telephone alarm system - 4- picture 4 5.Program of main unit 5.1program precautions ① the phone should be standard dtmf (double tone multi frequency). And the power of telephone is provided by ac power, so please pick receiver up instead of free hand when programming. ② main unit only can be ...

  • Page 8

    8-zone telephone alarm system - 5- 5.2specific operation entering into setup state well connect main unit with telephone line, power on main unit, and press “set” button at the back of main unit for 3 seconds, “set” indicator will be on, and wait for 2 seconds before picking telephone receiver up, a...

  • Page 9

    8-zone telephone alarm system - 6- instruction: after entering 03#, main unit will make a short “di” sound, and then you can enter 8 bit numbers ranges from 0 to 6, and press “#” to confirm, then it will make four short “di” sound, which means the setting is successful. Application: 1.When connectin...

  • Page 10

    8-zone telephone alarm system - 7- when main unit occurring alarm, it will make alarm sound till the alarm duration arrives, then main unit will close alarm sound automatically (if there are wireless siren, then it will close alarm sound of wireless external siren at the same time). Note: if the ala...

  • Page 11

    8-zone telephone alarm system - 8- 5.4 telephone setting how to set telephone numbers empty by default instruction: (a)during entering telephone number, every time entering a “*”, which means it will go on dialing after pausing for 2 seconds. And the number of “*” is subject to the difference of exc...

  • Page 12

    8-zone telephone alarm system - 9- enter 12#, after hearing a short “di” sound, then enter a “#”, and all indicator lights will be off one by one, then it will make four short “di” sound, which means the setting is successful. Example 2: delete all groups of telephone number enter 19#, after hearing...

  • Page 13

    8-zone telephone alarm system - 10- how to enter alarm monitor center accounts 0000 by default 05#aaaa# (aaaa should be 4 bits, which ranges from 0 to 9) instruction: entering 05#, it will make a short “di” sound, and enter 4 bits of alarm monitor center accounts, then press a “#” to confirm, it wil...

  • Page 14

    8-zone telephone alarm system - 11- 83# to register the third detector in the eighth zone (the first bit stands for zone number, and the latter bit stands for the number of detectors in this zone, and “#” means to confirm.) example 1: registering a pir detector in the third zone, and register a wire...

  • Page 15

    8-zone telephone alarm system - 12- light will be on as long as one detector has been learned in this zone. C. This directive only used to display the indicator lights, and it won't modify any settings. Example 1: learn one detector in the first zone, learn 2 detectors in the second zone, learn 3 de...

  • Page 16

    8-zone telephone alarm system - 13- learned in this zone, and if the indicator light is off, which means no remote controller has been learned in this zone. 2.This directive only used to display the indicator lights, and it won't modify any settings. Example 1: two remote controllers has been learne...

  • Page 17

    8-zone telephone alarm system - 14- ① emit indicator: if the light is on, which means it is sending signal, if the light cannot be on, please change the battery. ② arm in away home mode: press this key, main unit will make a short “di” sound, then the main unit will be in arm state of away home mode...

  • Page 18

    8-zone telephone alarm system - 15- main unit will make a short “di” sound every one second, and it arms in away home mode automatically when the leaving time preset arrives. (2)arm automatically when powered on after power on main unit, it will make a short “di” sound every one- second, and it arms...

  • Page 19

    8-zone telephone alarm system - 16- instruction: ① if the directive is correct, you will hear a short “di” sound. If the directive is incorrect, you will hear two long “di” sound. ② if you don't enter correct directives for 5 seconds, then you will hear alarm sound for 10 seconds again, then it will...

  • Page 20

    8-zone telephone alarm system - 17- and exit from setting state. If the code is correct, main unit will make a short “di” sound, and wait for directives for 20 seconds, and then you can enter as followings: 1# arm (in away home mode by default) 2# disarm 3# start alarm sound 0# exit from controlling...

  • Page 21

    Size: 33x63x16 (mm) 9.5wireless remote controller working voltage: 12v27a standby current: ≤5μa emit current: ≤10ma wireless emit frequency: 433.92mhz emit distance: 1-300m (in open area) size: 35x61x14 (mm) 10. Standard packing list 11. Optional packing list 12. Frequently ask questions 8-zone tele...

  • Page 22

    8-zone telephone alarm system - 19- false alarm 1. The installation of main unit 1. Install main unit and detector and detector can’t meet the according to install requirements requirements. 2. Replace the battery 2. Battery power is low backup battery can’t work 1. Battery is badly connected 1. Bat...

  • Page 23

    8-zone telephone alarm system - 20- 05#accounts# set contact id accounts (0000 by default) 09#new code#new code# modify user's code (000 000 by default) 11#telephone number# set the first group of telephone number. 12#telephone number# set the second group of telephone number. Deduce by analogy 18# ...

  • Page 24

    8-zone telephone alarm system - 21- 91## delete the first remote controller 92## delete the second remote controller deduce by analogy 98## delete the eighth remote controller 19# display zones, which code of detector has been learned 99# display zones, which code of remote controller has been learn...

  • Page 25

    8-zone telephone alarm system - 22- 0# exit from telephone answering state 1# arm immediately (arm in away home mode) 2# disarm immediately 3# alarm on the spot 4# monitor operate directives when receipt of alarm telephone 0# exit from operation remotely 1# arm immediately (arm in away home mode) 2#...

  • Page 26

    Warning: limits of this safe system as an advanced technical guard system, although it can reduce the occurrence of theft, robbery and fire, it can not promise to have no any above -mentioned accidents happens or have no any personnel casualty or property losses happens. And we invite you understand...