Karassn KS-258B User Manual - page 13
8-zone Telephone Alarm System
- 10-
<1>How To Enter Alarm Monitor Center Accounts 0000 by default
05#AAAA# (AAAA should be 4 bits, which ranges from 0 to 9)
Instruction: Entering 05#, it will make a short “Di” sound, and enter 4 bits
of alarm monitor center accounts, then press a “#” to confirm, it will make
four short “Di” sound, which means the setting is Successful.
36# Open report function when arm/disarm
37# Close report function when arm/disarm
Instruction: when main unit is connecting with monitor center, whether
to send arm/disarm report to monitor center
<3>How To Set Lower Power Report To Monitor Center
38# Open lower power report function
39# Close lower power report function
Instruction: Whether to inform manage center or not when main unit/
detector power lower.
6. Manager's Setting
How To Enter Manager's Program State
Well connect main unit as picture 4 in the fourth chapter, then power on
main unit.
Press “SET” button at the back of main unit for 3 seconds, “SET”
indicator will be on, and it needs to wait For 2 seconds after picking up receiver.
Enter 12*48# (12*48 is the code of manager and can not be modified)
* If the code is incorrect, then “SET” indicator will be off, and then exit
from setting state automatically.
* If the code is correct, it will make four short “Di” sounds, then you can
go on programming as following.
(After finishing programming, press “SET” button at the back of main
unit for 3 seconds, and the “SET” indicator will be off, and then exit from
setting state automatically.
<1>How To Recover User's Code
01#
Instruction: After entering 01#, all indicator lights will be off one by
one, and then it will make four short “Di” sound, which means the setting is
successful, and the user code will recover to the ex-factory state, that is 000 000.
<2>How To Register Detector
11# to register the first detector in the first zone
12# to register the second detector in the first zone
13# to register the third detector in the first zone
…………………………………………
81# to register the first detector in the eighth zone
82# to register the second detector in the eighth zone
<2> How To Set Report To Monitor Center When Arm/Disarm
Closed by default