Karassn KS-258B User Manual - page 12
8-zone Telephone Alarm System
- 9-
Enter 12#, after hearing a short “Di” sound, then enter a “#”, and all indicator
lights will be off one by one, then it will make four short “Di” sound, which
means the setting is successful.
Example 2: Delete all groups of telephone number
Enter 19#, after hearing a short “Di” sound, then enter a “#”, and all indicator
lights will be off one by one, then it will make four short “Di” sound, which
means the setting is successful.
<3> How To Set Telephone Attribute
Common alarm telephone number by default
04#XXXXXXXX# (X should be 8-bits, and they stand for the attribute
of 1-8 groups of telephone numberas following:)
Instruction: After entering 04#, main unit will make a short “Di” sound,
and enter 8 bits of number as above, then press a “#” to confirm, then it will
make four short “Di” sound, which means the setting is successful.
<4>How To Set Cycle Times Of Dialing 05 times by default
29#DD#
Instruction: “DD” is the cycle dialing times, which ranges from 03 to
15, and it should be 2 bits when entering.when main unit occurs alarm, it will
dial the alarm telephone number from the first group to the last group, and it
means one cycle. When the cycle dialing times you set arrives, main unit will
hang telephone up and stop dialing at the same time. But if main unit occurs
alarm again, it will cycle dial again.
<5>How To Open/Close Telephone Line Cut Detecting Function
Close by default
34#-------------Open telephone line cut detecting function
35#-------------Close telephone line cut detecting function
Telephone line cut detecting function: When the telephone line connected
with main unit is cut or there occur short-circuit, main unit will make an urgent
indicate sound.
<6>How To Set Ringing Times Of Operation Remotely
08 times by default (Only B model have this function)
28#DD#
Instruction: “DD” is the ringing times of operation remotely, which
should be 2 bits, and it ranges from 05to 15. When the ringing times you set
arrives, main unit will enter into remote setting state automatically.
And you can refer to 8.4 chapters for specific operations.
5.5 Alarm Monitor Center Setting (Only B model have this function)
Code Instruction
0 This group is unused at the moment
1 Common alarm telephone
2 CONTACT ID monitor center telephone
5 Power lower inform telephone