Foldout table stands:
The foldout table stands legs are located on the backside.
Simply unfold the stands on the back. Once the foldout table
stands are extended, place the weather station in an
appropriate location.
POSITIONING THE THERMO-HYGRO TRANSMITTER
The Thermo-hygro transmitter is supplied with a holder that may be attached to a wall
with the three screws supplied. Before securing the transmitter, ensure that the
868MHz signal is properly received. To attach to the wall, please follow the steps
below:
1.
Mark the wall using a pen through the holes in the holder to obtain the exact
drilling position.
2.
Drill holes in the wall at the points marked.
3.
Screw holder onto wall.
There is also double sided tape included with the wall mount. On smooth surfaces this can be used
instead of drilling holes. The mounting surface can, however, affect the transmission range. If for
example the unit is attached to a piece of metal, it may then either reduce or increase the
transmitting range. For this reason, we recommend not placing the unit on any metal surfaces or in
any position where a large metal or highly polished surface is in the immediate proximity (garage
doors, double glazing, etc.). Before securing in place, please ensure that the Weather station can
receive the 868MHz signal from the Thermo-hygro transmitter at the positions that you wish to
situate them.
The Thermo-hygro transmitter simply clicks in or out of the holder. When inserting or removing the
Thermo-hygro transmitter from the wall holder please hold both units securely.
CARE AND MAINTENANCE:
•
Extreme temperatures, vibration and shock should be avoided as these may cause damage
to the units and give inaccurate forecasts and readings.
•
When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or
scouring agents as they may mark the LCD and casings.
•
Do not submerge the units in water.
•
Immediately remove all low powered batteries to avoid leakage and damage. Replace only
with new batteries of the recommended type.
•
Do not make any repair attempts to the units. Return it to their original point of purchase for
repair by a qualified engineer. Opening and tampering with the units may invalidate their
guarantee.
•
Do not expose the units to extreme and sudden temperature changes, this may lead to rapid
changes in forecasts and readings and thereby reduce their accuracy.
SPECIFICATIONS:
Temperature measuring range:
Indoor
: -9.9ºC to +59.9ºC with 0.1°C resolution
14.2ºF to 139.8ºF with 0.2ºF resolution
(“OF.L” displayed if outside this range)
Outdoor
: -39.9ºC to +59.9ºC with 0.1°C resolution
-39.8ºF to +139.8ºF with 0.2ºF resolution
(“OF.L” displayed if outside this range)
Indoor humidity range
: 1% to 99% with 1% resolution