3.10 Espresso Group Water Temperature Regulation
3.10.1 Standard Temperature Adjustment
1. When the machine is On (ON/STBY solid green), press the button
ON//OFF
(27)
and keep it pressed for 3 seconds, the control light (22) and the one concerning
the set temperature start flashing. For example, if the set temperature is 95°C,
light (18) starts flashing.
2. In order to change the operating temperature, press and release the
Hot Water
button (23); every press of the button corresponds an increase of the
temperature of 1°C (with the flashing of the corresponding light). When the
maximum temperature of 97°C (20) is reached, the selection restarts from the
minimum temperature of 91°C (14) (cyclic mode).
3. Once you choose the desired temperature, in order to lock in this value, press
the
ON//OFF
(27) button, the machine will then go back to its normal functioning.
The value of the operating temperature of the machine is easily changed in order to
improve the final result in the cup depending on the coffee blend used and the user’s
personal preference.
3.10.2 Offset Temperature Adjustment
What Does Temperature Offset Do? / How Do I Use it?
The Vivaldi group design exhibits a temperature drop between where the group boiler
temperature probe is located and where the hot water exits the group. Consequently,
. Id
temperature indicated by the temperate lamps exactly matches the water temperature
aziale has partially accounted for this in its basic design.
how to tell what your current offset is, you can find out by
the temperature setting shown by the temperature lamps on the front panel may differ
from the water temperature at the group
eally, most users would prefer that the
exiting the group. LaSp
However, there are too many machine to machine electrical and mechanical variances
for this to be completely effective. That’s where the temperature offset comes in. The
programmable temperature offset allows a user with accurate group temperature
measuring equipment to enter an offset in the range of ±8˚C (for extended offset option
or 0 to -8˚C for standard offset option) in order to allow their machines temperature
lamps to exactly match the water temperature exiting the group.
Those purchasing new machines from Chris Coffee Service have had the temperature
offset professionally programmed used a Scace device. However, for those obtaining
the expanded offset capability via an upgrade, it is recommended that you note the
current offset prior to upgrading and then duplicate that offset using the instructions
below. If you do not know
entering the temperature offset mode and then following instructions in paragraph
3.10.2.