La Spaziale S1 Vivaldi II Owner's Manual - page 18
S1 Vivaldi II Owner’s Manual
Page 17
Consequently you must use the instructions provided in section 4.10.1 to set the
master temperature to 91ºC or 97ºC BEFORE using the instructions below. If this is not
done, the instructions below for entering the Extreme Temperature Set mode will work
as described, but once in that mode attempting to a raise or lower the temperature has
no effect.
Instructions for programming this mode AFTER setting the master temperature to 91ºC or
97ºC are:
• Start with the machine in Standby mode (ON/STBY light flashing).
• Press and hold the
Two Cup
button for ~3 seconds until lights 94ºC (17) and 95ºC(18)
come on indicating that the Extreme Temperature Function setting mode is active.
• If you start with the master temperature set to 97ºC, each time that the
Hot Water
button is pressed, lights 96ºC (19), 97ºC (20), and Econ (21) will switch on in
succession. Each light indicates a 1ºC increase. All three lights on = 100ºC.
• If you start with the master temperature set to 91ºC, each time that the
One Cup
button is pressed, lights 93ºC (16), 92ºC (15), and 91ºC (14) will switch on in
succession. Each light indicates a 1ºC decrease. All three lights on = 88ºC.
• Press the
Two Cup
button again to exit Extreme Temperature set mode and return
back to Standby mode
Notes:
When you change the temperature of the 91ºC and/or 97ºC buttons according to
the above instructions, the change only remains in effect until the temperature is
changed. For example, if you change the 91ºC selection by 3ºC to yield 88 ºC,
then later change the temperature to 93C, the next time you select 91ºC, you
will get 91ºC, not 88 ºC. If you wish to obtain 88ºC again you will need to follow
the above instructions to reprogram in the 3 ºC decrease.
4.12 Programmable Preinfusion
Note: only machines purchased or upgraded after 7/1/08 have this feature.
With the machine on (ON/STBY (22) lit and not blinking), press and hold the
ON/OFF
button(27) for three seconds until the ON/STBY (22) and the current preset temperature
lamps are both blinking. Then press the
BOILER
button (13) for 3 seconds. The temperature
plus ECON lamps now display the current time delay between when the group water solenoid
opens and when the pump is activation. This is the preinfusion time. If none of the lamps 14-
21 are lit, the preinfusion time is 0 seconds which means no preinfusion. Each press of the
BOILER
button (13) increases preinfusion time by 1 second and lights one more lamp up to a
maximum of 8 seconds when all of the temperature and ECON lamps (14-21) are lit. When
preinfusion is set to 8 seconds, another press of the
BOILER
button (13) resets the
preinfusion back to 0 seconds.