Summary of 12big Rack Fibre 8

  • Page 1

    Lacie 12big rack storage server user manual page 1 table of contents table of contents 1. Safety guidelines ........................................................................................................ 7 1.1. Safe handling .....................................................................

  • Page 2

    Lacie 12big rack storage server user manual page 2 table of contents 4.3.1. Activating the locks ........................................................................................................ 20 4.3.2. De-activating the locks ...................................................................

  • Page 3

    Lacie 12big rack storage server user manual page 3 table of contents 6.3.5. Event log configuration sub-menu .................................................................................. 40 6.3.6. Onboard lan configuration sub-menu ..................................................................

  • Page 4

    Lacie 12big rack storage server user manual page 4 table of contents 8.3.2.1. Removing a cooling fan ................................................................................. 59 8.3.2.2. Installing a cooling fan ...................................................................................

  • Page 5

    Lacie 12big rack storage server user manual page 5 table of contents 14. Ipmi command list ................................................................................................... 80 14.1. Chassis commands ......................................................................................

  • Page 6: Preface

    Lacie 12big rack storage server user manual page 6 preface notices the information in this document is subject to change without notice. While every effort has been made to ensure that all information in this document is accurate, the authors accept no liability for any er- rors that may arise. No p...

  • Page 7: 1. Safety Guidelines

    Lacie 12big rack storage server user manual page 7 safety guidelines 1.1. Safe handling caution: if this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. All plug-in modules and blanking plates are part of the fire enclosure a...

  • Page 8

    Lacie 12big rack storage server user manual page 8 safety guidelines fig. 02 - warning label – earthed mains socket provide a suitable power source with electrical overload protection to meet the requirements laid down in the technical specification. Bifurcated power cords must not be used with the ...

  • Page 9

    Lacie 12big rack storage server user manual page 9 safety guidelines the rj45 sockets on the motherboard/pci cards are for ethernet connection only and must not be connected to a telecommunica- tions network. Drives are fragile and must be handled with care during removal/ replacement. 1.3. Rack sys...

  • Page 10: 2. System Overview

    Lacie 12big rack storage server user manual page 10 system overview 2.1. The 12big rack storage server the 12big rack storage server is a 2u sized disk drive enclosure, housing up to twelve low profile (1 inch high), 3.5 inch form factor drives of the following types: ✦ 3.0/6.0gb/s sas (up to 15000 ...

  • Page 11

    Lacie 12big rack storage server user manual page 11 system overview the high speed serial architecture of the 12big rack storage server provides three 4-lane connections from the em card to the hba. Module and major component locations are shown in fig. 07 . Fig. 08 - module locations 2.3. Enclosure...

  • Page 12

    Lacie 12big rack storage server user manual page 12 system overview the connectors are shown in fig. 10 . Fig. 10 - atx server i/o components 2.4.2. Pci express slots the motherboard has seven pci express slots, as detailed in table 02 . Table 02 - pci express slots slot number color type connector ...

  • Page 13

    Lacie 12big rack storage server user manual page 13 system overview be shut down using the procedure in 4.2. Powering off the enclosure . – system reset: reboots the hardware and firmware. Use the tip of a ballpoint pen to press the recessed button. – id led: toggles the blue enclosure identificatio...

  • Page 14

    Lacie 12big rack storage server user manual page 14 system overview fig. 13 - cooling fan module airflow is from front to rear, with cooling air being drawn across the drives, through the fans and pressurizing the rear of the enclosure. The pressurized rear allows the psu to draw the air that it req...

  • Page 15

    Lacie 12big rack storage server user manual page 15 system overview 2.10.5. Blanking plates blanking plates must be fitted in any vacant psu bay or pci card slots at the rear of the enclosure to maintain airflow and allow cor- rect operation. Caution: operation of the enclosure with any modules miss...

  • Page 16: 3. Installation

    Lacie 12big rack storage server user manual page 16 installation 3.1. Introduction in this chapter, you are shown how to install the 12big rack storage server into an industry standard 19 inch rack cabinet. Note: 12big rack storage server are supplied and delivered fully populated with drive carrier...

  • Page 17

    Lacie 12big rack storage server user manual page 17 installation be overloaded by the total number of units installed in the rack. Consideration of the electrical power consumption rat- ing shown on the unit’s nameplate should be used when ad- dressing these concerns. ✦ the electrical distribution s...

  • Page 18

    Lacie 12big rack storage server user manual page 18 installation 3.4. Installation 3.4.1. Equipment the following equipment is required for installation: ✦ the enclosure chassis, including the following: – backplane pcb. – atx motherboard. – enclosure management card (em card). – ops panel. – blanki...

  • Page 19

    Lacie 12big rack storage server user manual page 19 installation fig. 20 - latch position 3.4.3. Installing the modules 12big rack storage servers are supplied and delivered populated with all components and plug-in modules installed. For information on removal/replacement of plug-in modules, refer ...

  • Page 20: 4. Operation

    Lacie 12big rack storage server user manual page 20 operation 4.1. Powering on the enclosure caution: do not operate the subsystem until the ambient tem- perature is within the specified operating range. If the drives have been recently installed make sure they have had time to acclimatize before op...

  • Page 21

    Lacie 12big rack storage server user manual page 21 operation refer to chapter 7. Troubleshooting and problem solving for details of any fault indication. Fig. 22 - ops panel leds and switches table 04 - ops panel leds led status power active ✦ constant green: system has full power and is running. ✦...

  • Page 22

    Lacie 12big rack storage server user manual page 22 operation 4.4.3. Drive carrier leds each drive carrier module incorporates a green and amber led, shown in fig. 24 . Fig. 24 - drive carrier leds table 07 - disk drive leds led definition activity ✦ flickering green: the drive is powered and has ac...

  • Page 23

    Lacie 12big rack storage server user manual page 23 operation 4.4.6.2. Network port leds the network port leds are defined in table 10 . Refer to your atx server documentation for full details of the led states. Table 10 - network port leds led led state description left off no network connection so...

  • Page 24: 5. The Management Gui

    Lacie 12big rack storage server user manual page 24 the management gui 5.1. Connecting to the web management interface before connecting to the management gui, the baseboard man- agement ip address needs to be confirmed. To obtain the address or configure it: 1. Enter the bios setup. 2. Go to set la...

  • Page 25

    Lacie 12big rack storage server user manual page 25 the management gui 5.3. Sensor 5.3.1. Reading this section offers a visual display of all board sensor readings. The values can be manually refreshed. Below is the list of all onboard sensors. Table 11 - on-board sensors sensor number sensor name s...

  • Page 26

    Lacie 12big rack storage server user manual page 26 the management gui sensor number sensor name sensor type event/reading type oem discrete readings available 25 powerok_0vddq power supply sensor specific none 26 powerok_01.8v power supply sensor specific none 27 powerok_1vcore power supply sensor ...

  • Page 27

    Lacie 12big rack storage server user manual page 27 the management gui 5.4. Control 5.4.1. Remote power/reset this section allows you to power down, shutdown, reset and power cycle the board. Table 12 - enclosure impact command payload impact reset immediately reboots the enclosure in the same way a...

  • Page 28

    Lacie 12big rack storage server user manual page 28 the management gui 3. Start the firmware upgrade by clicking “start upgrade component(s)”. The progress bars will display the upgrade sta- tus of the components. Fig. 28 - firmware upgrade step 3 4. If the upgrade is successful, the “activate and r...

  • Page 29: 6. Bios Settings

    Lacie 12big rack storage server user manual page 29 bios settings 6.1. Ami bios setup program all relevant information for operating the board and connected pe- ripherals are stored in the cmos memory backed-up by a battery or in the main bios flash and eeprom. 6.1.1. Accessing the bios setup utilit...

  • Page 30

    Lacie 12big rack storage server user manual page 30 bios settings 6.1.2. Menu bar the menu bar at the top of the window lists these selections: table 13 - menu bar menu selection description main use this menu for basic system configura- tion. Advanced use this menu to set the advanced fea- tures av...

  • Page 31

    Lacie 12big rack storage server user manual page 31 bios settings 6.2. Main menu table 15 - main menu feature options description setup help version x.Yy displays the bios core version. N/a, display only. Build date yymmdd displays the bios build date in the format yymmdd. Id bios id code displays t...

  • Page 32

    Lacie 12big rack storage server user manual page 32 bios settings feature options description setup help trusted computing n/a "press enter to go to sub screen ""trusted computing""." usb configuration n/a "press enter to go to sub screen ""usb configuration""." virtualization configuration n/a "pre...

  • Page 33

    Lacie 12big rack storage server user manual page 33 bios settings feature options description setup help numa support ✦ enabled ✦ disabled enable/disable numa (non-uniform memory access) support. Enable: efficiently execute software for numa aware os. Disable: better memory access performance for no...

  • Page 34

    Lacie 12big rack storage server user manual page 34 bios settings table 23 - north bridge configuration sub-menu feature options description setup help nb revision n/a display current nb revision id. Current qpi frequency n/a display current qpi frequency speed in gt/s intel quickdata technology dma...

  • Page 35

    Lacie 12big rack storage server user manual page 35 bios settings feature options description setup help ratio status ✦ unlocked ✦ locked lock status of the fsb multiplier. Sets the ratio between cpu core clock and the fsb frequency. Ratio actual value x displays current processor fsb multiplier val...

  • Page 36

    Lacie 12big rack storage server user manual page 36 bios settings feature options description setup help intel® ht technology ✦ enabled ✦ disabled delivers thread-level parallelism on each processor result- ing in more efficient use of processor resources, higher processing throughput, and improved ...

  • Page 37

    Lacie 12big rack storage server user manual page 37 bios settings feature options description setup help c state package limit setting ✦ auto ✦ c1 ✦ c3 ✦ c6 ✦ c7 advanced power management state (c-state) that signifi- cantly reduces the power of the processor during idle pe- riods. Selected option w...

  • Page 38

    Lacie 12big rack storage server user manual page 38 bios settings 6.3.4.1. Ahci configuration sub-menu table 28 - ahci configuration sub-menu feature options description setup help ahci bios support ✦ enabled ✦ disabled support ahci mode during bios control. Enables the ahci control- ler to operate ...

  • Page 39

    Lacie 12big rack storage server user manual page 39 bios settings 6.3.4.3. Ide configuration sub-menu table 30 - ide configuration sub-menu feature options description setup help primary ide master n/a press enter to go to sub screen “primary ide master”. While entering setup, bios auto detects the ...

  • Page 40

    Lacie 12big rack storage server user manual page 40 bios settings 6.3.5. Event log configuration sub-menu table 32 - event log configuration sub-menu feature options description setup help view event log enter view all unread events in the event log. Mark all events as read enter mark all unread eve...

  • Page 41

    Lacie 12big rack storage server user manual page 41 bios settings 6.3.7. Pci slots configuration sub-menu table 34 - pci slots configuration sub-menu feature options description setup help expansion rom on pci slot 1 ✦ enabled ✦ disabled enabled: loads expansion rom on pci slot. Disabled: expansion ...

  • Page 42

    Lacie 12big rack storage server user manual page 42 bios settings feature options description setup help terminal type ✦ ansi ✦ vt100 ✦ vtutf8 configures the type of console emulation used for both serial ports. Vt-utf8 combo key support ✦ enabled ✦ disabled vt-utf8 adds escape sequences for f1 to f...

  • Page 43

    Lacie 12big rack storage server user manual page 43 bios settings 6.3.11. Usb configuration sub-menu table 38 - usb configuration sub-menu feature options description setup help list usb d e v i c e ( s ) detected. This feature appears when the bios post has detected usb device(s). Usb 2.0 controlle...

  • Page 44

    Lacie 12big rack storage server user manual page 44 bios settings 6.3.12. Virtualization configuration sub-menu table 40 - virtualization configuration sub-menu feature options description setup help sr-iov supported disabled single root i/o virtualiza- tion. Intel vt-d disabled intel® virtualizatio...

  • Page 45

    Lacie 12big rack storage server user manual page 45 bios settings feature options description setup help user password ✦ no ✦ yes indicates the status of the user password. Change supervisor password enter the supervisor password can be installed or changed. Install or change the pass- word. User ac...

  • Page 46

    Lacie 12big rack storage server user manual page 46 bios settings feature options description setup help cd/dvd drives n/a "press enter to go to sub screen ""cd/dvd drives""." specifies the boot device pri- ority sequence from available cd/dvd drives. Usb drives n/a "press enter to go to sub screen ...

  • Page 47

    Lacie 12big rack storage server user manual page 47 bios settings 6.5.2. Boot device priority sub-menu table 45 - boot device priority sub-menu feature options description setup help 1st ... Nth boot device type: boot de- vice specifies the priority of the available boot sources. The list includes u...

  • Page 48

    Lacie 12big rack storage server user manual page 48 bios settings 6.5.8. Other drives sub-menu table 51 - other drives sub-menu feature options description setup help 1st ... Nth drive specifies the boot sequence from the available devices. 6.6. System management menu table 52 - system management me...

  • Page 49

    Lacie 12big rack storage server user manual page 49 bios settings feature options description setup help gateway address n/a "press enter to go to sub screen ""gateway address""." active lan channel number ✦ none ✦ 01 ✦ 02 ✦ both each interface has a channel number that is used when configuring the ...

  • Page 50

    Lacie 12big rack storage server user manual page 50 bios settings 6.6.4. Subnet mask sub-menu table 56 - subnet mask sub-menu feature options description setup help channel number each interface has a channel number that is used when configuring the channel and for routing messages be- tween channel...

  • Page 51

    Lacie 12big rack storage server user manual page 51 bios settings 6.6.6. Ipmi device and firmware information sub-menu table 58 - ipmi device and firmware information sub-menu feature options description setup help product id product id code (2 bytes) "displays cpu blade product id from ipmi ""get d...

  • Page 52

    Lacie 12big rack storage server user manual page 52 bios settings feature options description setup help product version number manufacturer pcb version displays the cpu blade pcb revision number. Product serial number varies displays the cpu blade serial number. 6.7. Exit menu table 60 - exit menu ...

  • Page 53

    Lacie 12big rack storage server user manual page 53 bios settings 6.9. Console redirection (vt100 mode) the vt100 operating mode allows remote setup of the board. This configuration requires a remote terminal that must be connected to the board through a serial communication link. 6.9.1. Requirement...

  • Page 54

    Lacie 12big rack storage server user manual page 54 troubleshooting and problem solving 7.1. Overview the 12big rack storage server includes an enclosure services pro- cessor and associated monitoring and control logic to enable it to diagnose problems within the em card, ops panel, cpu(s) and dimm(...

  • Page 55

    Lacie 12big rack storage server user manual page 55 troubleshooting and problem solving 7.4. Led/audible alarm interpretation the following tables summarize the various states of the leds and audible alarm and their meaning. Some states are duplicated in this section to make it easier to search for ...

  • Page 56

    Lacie 12big rack storage server user manual page 56 troubleshooting and problem solving ops panel fault led audible alarm other led meaning and required action constant constant no fan leds constant failure state (temperature in range where dam- age could occur): check ambient temperature and increa...

  • Page 57

    Lacie 12big rack storage server user manual page 57 module removal and replacement 8.1. Overview the 12big rack storage server includes an enclosure services pro- cessor and associated monitoring and control logic to enable it to diagnose problems within the enclosure’s power, cooling and drive syst...

  • Page 58

    Lacie 12big rack storage server user manual page 58 module removal and replacement 3. Squeeze the locking tab to the left ( fig. 31 ). Fig. 31 - removing a psu (1) 4. Grip the handle and withdraw the psu from the mounting cage ( fig. 32 ). Fig. 32 - removing a psu (2) 8.3.1.2. Installing a power sup...

  • Page 59

    Lacie 12big rack storage server user manual page 59 module removal and replacement 8.3.2. Cooling fans the 12big rack storage server incorporates ten cooling fans, housed in a cooling cage. Fan modules are individually installed. Important info: a faulty cooling fan must be replaced by a fully opera...

  • Page 60

    Lacie 12big rack storage server user manual page 60 module removal and replacement 8.3.3.1. Removing a drive carrier caution: damage can occur to a drive if it is removed while still spinning. If possible use the operating system to spin down the drives prior to removal. If this is not possible we r...

  • Page 61

    Lacie 12big rack storage server user manual page 61 module removal and replacement important info: make sure that the carrier is orientated so that the drive is uppermost and the handle opens from the left, as shown in fig. 41 . 3. Gently slide the drive carrier all the way into the enclosure. 4. Ca...

  • Page 62

    Lacie 12big rack storage server user manual page 62 module removal and replacement caution: there is a danger of explosion if the battery is replaced by an incorrect type. Dispose of used batteries in accordance with the manufacturer’s in- structions and national regulations. 8.4.2. Replacing memory...

  • Page 63

    Lacie 12big rack storage server user manual page 63 module removal and replacement 8.5. Replacing pci cards note: this procedure is only for authorized customers using au- thorized parts. Fig. 46 - motherboard pci slots 1. To access a pci card, release the enclosure top cover by turn- ing the lock m...

  • Page 64: 9. Gem Enclosure Firmware

    Lacie 12big rack storage server user manual page 64 gem enclosure firmware 9.1. Alarm states the gem firmware supports the following alarms states: table 67 - alarm states alarm state mode action without mute button pressed with mute button pressed s0 normal mode silent beep twice s1 fault mode one ...

  • Page 65

    Lacie 12big rack storage server user manual page 65 gem enclosure firmware status severity alarm state low warning temperature alert warning s1 high warning temperature alert warning s1 over temperature alarm fault - critical s1 i 2 c bus failure fault - loss of redundancy s1 em card interface modul...

  • Page 66

    Lacie 12big rack storage server user manual page 66 upgrading the firmware 10.1. Important notes upgrading the firmware consists of two steps, to be performed in this order: ✦ upgrading the x86 subsystem. ✦ upgrading the gem subsystem. Note: it is important to note that the x86 subsystem upgrade pro...

  • Page 67

    Lacie 12big rack storage server user manual page 67 upgrading the firmware tar zxvf ipmitool-1.8.11.Tar.Gz 3. Get the latest development version of ipmitool from the cvs sourceforge server: cvs -d:pserver:anonymous@ipmitool.Cvs. Sourceforge.Net:/cvsroot/ipmitool login cvs -z3 -d:pserver:anonymous@ip...

  • Page 68

    Lacie 12big rack storage server user manual page 68 upgrading the firmware manually. 4. Download the updated fan controller chip firmware and con- figuration. This will be a file of the form: 0955682-xx_emcard_fanctrl_xx.Gff where the ‘xx’ symbols represent version numbers. 5. The em card will be re...

  • Page 69

    Lacie 12big rack storage server user manual page 69 upgrading the firmware 10.3.4. Version checking after the firmware upgrade the cli ver command should return ver- sion numbers for the following: em card firmware em card firmware date em card bootloader em card config crc em card vpd structure em ...

  • Page 70

    Lacie 12big rack storage server user manual page 70 technical specifications 11.1. Dimensions table 70 - dimensions rack enclosure inches millimeters height 3.46 87.9 width across mounting flange 19.01 483 width across body of enclosure 17.68 449 depth from rack posts to rear of pci bulkhead 26.82 6...

  • Page 71

    Lacie 12big rack storage server user manual page 71 technical specifications table 73- environment airflow system must be operated with low pressure rear exhaust installation. Back pressure created by rack doors and obstacles must not exceed 5 pascals (0.5mm water gauge) altitude, operational 0 to 2...

  • Page 72

    Lacie 12big rack storage server user manual page 72 technical specifications 11.5. Cooling fan table 75 - cooling fans number 10 type single rotor high speed axial speed control pwm speed control in 5 banks of 2 connection hot pluggable connector to enclosure management card tacho outputs individual...

  • Page 73

    Lacie 12big rack storage server user manual page 73 standards & regulations 12.1. International standards the 12big rack storage server complies with the requirements of the following agencies and standards: ✦ ce to en 60950-1 ✦ cb report to iec 60950-1:2005 (2nd edition) ✦ ul & cul to ul 60950-1 2n...

  • Page 74

    Lacie 12big rack storage server user manual page 74 standards & regulations 12.7. Ac power cords 12.7.1. United states must be nrtl listed (national recognized test laboratory, e.G. Ul) table 79 - us power cords cord type sv or svt, 18 awg minimum, 3 conductor, 4.5 m max length. Plug nema 5-15p grou...

  • Page 75

    Lacie 12big rack storage server user manual page 75 post 13.1. Introduction during power on self-test, the eight leds on the back of the moth- erboard (see fig. 25 ) show the status in a binary pattern as follows: table 81 - motherboard led values led d7 d6 d5 d4 d3 d2 d1 d0 decimal 128 64 32 16 8 4...

  • Page 76

    Lacie 12big rack storage server user manual page 76 post 13.3. Post code checkpoints table 83 describes the checkpoints that occur during the power on self-test (post) portion of the bios. These codes are shown on the motherboard leds as described in section 13.1. Introduction . All of these codes c...

  • Page 77

    Lacie 12big rack storage server user manual page 77 post checkpoint description 3c mid post initialization of chipset registers. 40 detect different devices (parallel ports, serial ports, and coprocessor in cpu, … etc.) suc- cessfully installed in the system and update the bda, ebda…etc. 50 programm...

  • Page 78

    Lacie 12big rack storage server user manual page 78 post 13.4. Dim code checkpoints the device initialization manager (dim) gets control at various times during bios post to initialize different system busses. Table 84 de- scribes the main checkpoints where the dim module is accessed. These codes ar...

  • Page 79

    Lacie 12big rack storage server user manual page 79 post 13.5. Memory initialization error codes these codes are shown on the motherboard leds as described in section 13.1. Introduction . Table 87 - memory initialization error codes checkpoint description e8 memory error - no memory installed. Ea me...

  • Page 80: 14.  Ipmi Command List

    Lacie 12big rack storage server user manual page 80 ipmi command list 14.1. Chassis commands netfn: 00h, 01h; lun: 0. Table 89 - ipmi chassis commands code command 0h get chassis capabilities 1h get chassis status 2h chassis control 4h chassis identify 14.2. Sensor event commands netfn: 04h, 05h; lu...

  • Page 81

    Lacie 12big rack storage server user manual page 81 ipmi command list code command 32h enable message channel receive 33h get message 34h send message 35h read event message buffer 37h get system guid 38h get channel authentication capabilities 39h get session challenge 3ah activate session 3bh set ...

  • Page 82

    Lacie 12big rack storage server user manual page 82 ipmi command list 14.5. Transport commands netfn: 0ch, 0dh; lun: 0. Table 93 - ipmi transport commands code command 1h set lan configuration parameters 2h get lan configuration parameters 3h suspend bmc arps 4h get ip/udp/rmcp statistics 20h sol ac...

  • Page 83: 15.  Glossary

    Lacie 12big rack storage server user manual page 83 glossary bmc baseboard management controller dp dual processor em card enclosure management card eusb embedded usb gem genesis enclosure management hba host bus adapter ipmb intelligent platform management bus ipmi intelligent platform management i...