Lampert PUK D3 Operating Manual - page 10
© Lampert Werktechnik GmbH
2017
9
g) Selection of the memory location and saving the
settings (if activated in the settings). Storing custom
welding parameters (20 memory slots)
h)
Input and saving of the desired program (if activated in
the settings)
5.3 SWITCHING ON THE DEVICE
First, carefully open the gas tank valve. Then switch the
master mains switch (2) on the rear of the housing to the
“I” position – the display shows the safety prompt
regarding eye protection and the operating manual.
Confirm your compliance with the safety instructions by
pressing the rotary controller or by touching the
touchscreen.
5.4 ADJUSTING FOR THE CORRECT GAS FLOW
The PUK D3 only works with shielding gas
connected and sufficient gas flow. If no shielding
gas is connected or the gas flow is insufficient, then a
corresponding error message is shown in the display and
the device fails to weld in the TIG-mode (starting and
expert level, and in the stored custom settings).
PLEASE CONSIDER THAT GOOD WELDING RESULTS CAN ONLY BE ACHIEVED WITH A CORRECTLY
ADJUSTED GAS FLOW.
In order to configure the correct gas flow, activate the
"Gas valve" in the "Settings" menu (see chapter 5.5). This
opens the gas valve in the welding device. Now set the
flow regulator to the correct flow rate of approx. 2 - 3
litres/min. In doing so, also observe the instructions
provided with the flow regulator. Once the gas volume is
correctly adjusted, close again the "Gas valve" function by
pressing the corresponding button.
5.5 OPERATING LEVEL "SETTINGS"
The "Settings" user level can be used to modify basic settings and launch various test functions.
•
Gas valve:
Pressing the corresponding button
causes the gas valve to be
opened. This function is important
in order to set the correct gas flow on the flow regulator
(see chap. 5.4). Pressing the button again causes the
gas valve to be closed. In addition, any other operation of
the device will automatically quit that function.
•
Filter-Test:
P
ressing this button causes a
shading of the eye protection filter.
This enables correct function of the
eye protection filter to be checked.
Pressing the button again quits the test.
•
LED light:
P
ressing the button enables the
brightness of the LED lamp on the
welding microscope to be adjusted in 3 steps or to be
switched off.
•
Program memory:
You can activate or deactivate the
saving and calling functions for
programs
that
you
created
yourself here. If this menu is activated, it appears as an
additional user level. The user levels can be toggled by
pressing
the
rotary
controller
for
1
second.
•
Expert Menü:
The expert menu can be activated
here. If this menu is active, it
appears as an additional user level. The user levels can
be toggled by pressing the rotary controller for 1 sec.
•
Fixation:
Pressing this button activates or
deactivates the operating menu
for fixation welding. If this menu is
activated, it appears as an additional user level. The user
levels can be toggled by pressing the rotary controller for
1 sec.