4.2 DESCRIPTION OF THE REAR OF THE DEVICE
(Fig. 2)
(1)
FUSEBOX ("Fuse")
(2)
MASTER MAINS SWITCH as well as
AC POWER SOCKET
(for connecting the mains cable)
(3)
CONNECTION SOCKET FOR EYE PROTECTION SYSTEM
AND LED MICROSCOPE ILLUMINATION
(4)
CONNECTION SOCKET FOR FOOT SWITCH
(5)
TYPE PLATE
(6)
SERIAL NUMBER
(7)
PROTECTIVE GAS CONNECTION ("Argon Gas")
For 6.0 mm diameter pressure hose (max. 4,0 bar / 58 psi)
(8)
APPROVED MAINS VOLTAGE FOR THIS DEVICE
4.3 CONNECT EYE PROTECTION AND LED ILLUMINATION OF THE WELDING MICROSCOPE TO THE PUK:
The circular connector for the eye protection system and
the LED illumination should be inserted into the
connecting socket (3) on the rear of the PUK welding
device (marked in red and yellow colour) and is to be
tightened in place with the coupling nut (hand tight)..
WARNING!
ONLY SUITABLE ORIGINAL EYE PROTECTION SYSTEMS FROM LAMPERT MAY BE CONNECTED TO THE
WELDING SYSTEM! OTHER EYE PROTECTION SYSTEMS ARE NOT APPROVED AND CAN LEAD TO
PERMANENT HEALTH DAMAGE OR DAMAGE TO THE WELDING DEVICE.
ALWAYS OBSERVE THE OPERATING INSTRUCTIONS FOR THE CONNECTED EYE PROTECTION SYSTEM
4.4 CONNECT SHIELDING GAS SUPPLY:
Fasten the suitable flow regulator with the corresponding
tool to the shielding gas tank. ATTENTION: In doing so,
always
observe
the
enclosed
special
operating
instructions provided. (Where possible, use argon with
min. 99.9 % purity, e.g. "Argon 4.6"). The pressure hose is
to be fastened by hand with the help of the quick coupling
adapter to the flow regulator as well as the shielding gas
connector (7) on the rear of the device.
CHECK REGULARLY THAT ALL OF THE HOSE CONNECTIONS AND GAS HOSES ARE IN OPTIMAL
CONDITION, ARE PROPERLY FASTENED AND ARE AIRTIGHT!
1
3
5
4
2
8
7
6